1,4-Diiodobenzene Manufacturers, with SDS GHS MSDS Sheet
Supplier, Manufacturer, Exporter of 1,4-Diiodobenzene, Muby Chemicals of Mubychem Group, established in 1976, is the original manufacturers of Specialty Chemicals, Pharmaceutical Excipient, Fragrance Food & Flavor chemicals, Reagent Grade Chemicals, Shale Gas Fracturing Chemicals in India. Mubychem Group has several manufacturing facilities spread across Western India and world wide contacts and toll manufacturers. We are exporting globally to countries like USA, Canada, Europe, UAE, South Africa, Tanzania, Kenya, Egypt, Nigeria, Cameroon, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Dubai, Korea, Vietnam, Thailand, Malaysia, Indonesia, Australia, China, Germany, France, Italy, Portugal etc.
The products are offered as per required specifications and in correct shape and size in mm or meshs or microns as specified by the buyer.
The participating units have one or more accreditations like FDA - cGMP and GLP approval, ISO-9001 Certified, "REACH" Registered, ISO-14001, ISO/IEC 17025, ISO-22000, FSSC 22000, ISO 45001, Kosher Certified, Halal Certified, HACCP, FSSAI. We offer Commercial Pure & IP BP EP Ph Eur USP NF JP FCC Food Grade Analytical Reagent Grades of Chemicals
Bookmark this Web Site -- or -- Email This Page Info to a Colleague or Yourself Search our website here:
1,4-Diiodobenzene: CAS Number: 624-38-4, EINECS EC Number: 210-842-2, Molecular Formula: C6H4I2, Molecular Weight: 329.90, HS Code ---**
How big is your requirement or how small
We serve it all.Specifications, Safety Data Sheet, Manufacturing process details, Wholesale retail buy sell prices, Uses etc available on line in these pages for 1,4-Diiodobenzene.
For SDS MSDS Sheet Click
SDS MSDS Sheet of 1,4-Diiodobenzene Manufacturers1,4-Diiodobenzene
Pure Suppliers
1,4-Diiodobenzene is used in wide range of medicals industrial applocations as well as in human and animal nutrition products such as antiseptics and disinfectants, pharmaceutical intermediates, polarizing films for liquid crystal display [LCD] chemicals. 1,4-Diiodobenzene is soluble in ether and ethanol and insoluble in water. It is light sensitive.
Specifications of 1,4-Diiodobenzene:
CAS number: 624-38-4
Molecular formula: C6H4I2
Molecular weight: 329.91
Description: White to yellowish shining crystals.
Melting point: Between 128C and 132C
Boiling point: 285C
Flash point: 285C
Solubility: Soluble in ether and ethanol and insoluble in water.
Purity: minimum 99.00 %.We manufacture and supply iodine chemicals or derivatives a under:
Iodoquinol or Diiodohydroxyquinoline
5-Iodoanthranilic acid or 2-Amino-5-Iodobenzoic acid
Methyltriphenylphosphonium Iodide
Manufacturers:
MUBY CHEMICALS
Ambernath Mumbai, Ankleshwar Gujarat, India
TEL: (OFFICE) +912223770100, +912223726950
Current Date Time in India GMT+5:30e-mail: info@mubychem.com
USA, Canada, Mexico and other American
neighbouring buyers may
e-mail: us@mubychem.com
Call toll-free 1-877-682-9243 (1-877-MUBYCHEM)
Copyright and Usual Disclaimer is Applicable.
Last 21 April, 2024
Exporters to USA Canada UAE Europe South Africa Tanzania Kenya Uganda Egypt Nigeria Turkey Mexico Brazil Argentina Chile Dubai etc.
Global or International Suppliers, Exporters, Importers, Manufacturers
I shall pass through this world, but once. If therefore, there is any good that I can do, or if there is any favor that I can show to a fellow human being, let me do it now. Let me not defer or neglect it. For I shall not tread this way again
1,4-Diiodobenzene SDS, Safety Data Sheet
MSDS Sheet, Material Safety Data Sheet 16-Oct-20Section 1 - Chemical Product and Identification
Product Name & Other Names: 1,4-Diiodobenzene
CAS Number: 624-38-4
EINECS EC Code: 210-842-2
Chemical Formula: C6H4I2
Molecular Weight: 329.90
Relevant uses and uses advised against (if any): Laboratory Chemicals and Industrial Manufacturing Use.
Supplier: As per letterhead.Section 2 - Hazards Identification
GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.
This substance is not classified as dangerous according to Directive 67/548/EEC.Labeling according GHS & Regulation (EC) No 1272/2008
GHS Label Elements
NONESignal Word: None
Hazards not otherwise classified (HNOC):
May causes mild skin irritation.
May causes mild eye irritation.Precautionary statements:
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P262: Do not get in eyes, on skin, or on clothing.
P281: Use personal protective equipment as required.
P302+P352: IF ON SKIN: Wash with plenty of soap and water.
P303+P361+P353: IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
P304 + P340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337+313: If eye irritation persists get medical advice/attention.Section 3 - Composition, Information on Ingredients
Product Name & Other Names: 1,4-Diiodobenzene
CAS Number: 624-38-4
EINECS EC Code: 210-842-2Section 4 - First Aid Measures
Always seek medical advice after the first aid treatment.
Eyes: Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid.
Skin: Flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Get medical aid if irritation develops or persists. Wash clothing before reuse.
Ingestion: If victim is conscious and alert, give 2-4 cupfuls of milk or water. Get medical aid. Wash mouth out with water.
Inhalation: Remove from exposure to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical aid if cough or other symptoms appear.
Notes to Physician: None.Section 5 - Fire Fighting Measures
General Information: Water runoff can cause environmental damage. Dike and collect water used to fight fire. Wear appropriate protective clothing to prevent contact with skin and eyes. Wear a self-contained breathing apparatus (SCBA) to prevent contact with thermal decomposition products. Closed containers may explode from heat of a fire.
Extinguishing Media: For small fires, use water spray, dry chemical, carbon dioxide or chemical foam.
Special hazards arising from the substance: Hydrogen iodide, iodine and carbon oxides.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures under fire conditions, it may produce toxic or irritating fumes.Section 6 - Accidental Release Measures
Personal precautions, protective equipment, and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment Cleanup procedures and Storage: Do not inhale dust, vapors, mist, or gas. Avoid dust formation. Contain spilled material. Cover with an inert, non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite). Use a shovel to put the material into a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and allow to evacuate as per law.Section 7 - Handling and Storage
Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid contact with skin and eyes. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like strong oxidizing agents and acids. Store protected from moisture heat and light.Section 8 - Exposure Controls, Personal Protection
Engineering Controls: Good general ventilation should be sufficient to control airborne levels. Facilities storing or utilizing the material should be equipped with an eyewash facility and a safety shower.
Exposure Limits: Not listed by ACGIH NIOSH & OSHA-Final PELs.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice. Wash hands after handling.Section 9 - Physical and Chemical Properties
Physical State & Appearance: Solid. White to yellowish crystals.
Odor: Odorless.
Odor threshold: Not available.
pH: Not available.
Relative density: 2.88 (literature)
Boiling Point: 285C
Melting Point: 128C and 132C
Flash Point: 285C
Auto-ignition temperature: Not available.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor pressure: Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility: Soluble in ether and ethanol and insoluble in water.
Viscosity: Not available.
Chemical Formula: C6H4I2
Molecular Weight: 329.90Section 10 - Stability and Reactivity
Chemical Stability: Stable.
Conditions to Avoid: High temperatures, light, exposure to moist air or water Strong acids, Strong oxidizing agents.
Hazardous Decomposition Products: Toxic fumes of iodine or hydrogen iodide and carbon oxide.
Hazardous Polymerization: Has not been reported.Section 11 - Toxicological Information
LD50 Oral - Rat - Not available
Carcinogenicity: Not listed by ACGIH, IARC, NIOSH, NTP, or OSHA.
Epidemiology: No information reported.
Teratogenic: No information reported.
Neurotoxicity: No information reported.Section 12 - Ecological Information
Toxicity to fish: LC50 - No information reported.
Environmental: No information reported.
Results of PBT and vPvB assessment: No information reported.Section 13 - Disposal Considerations
Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. US EPA guidelines for the classification determination are listed in 40 CFR Parts 261.3. Additionally, waste generators must consult state and local hazardous waste regulations to ensure complete and accurate classification.
Section 14 - Transport Information
DOT USA & ADR/RID Europe: Not dangerous goods
IMDG: Not dangerous goods
IATA: Not dangerous goods.Section 15 - Regulatory Information
USA Regulations:
Section 16 - Additional Information
SARA 302 Components: Not listed.
SARA 313 Components: Not listed.
SARA 311/312 Hazards: No SARA Hazards
California Prop. 65 Components: Not listed.Disclaimer:
**************************
Our company provides this MSDS sheet in good faith but makes no representation as to its comprehensiveness or accuracy. This SDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. The above information has been compiled from various sources and has the possibility of discrepancy and being out-dated information. Individuals receiving the information must exercise their independent judgment and do further search in determining its appropriateness for a particular purpose. In no case shall our company be liable to loss or damages by the product user.
**************************