2-Iodobenzoic Acid Manufacturers, with SDS GHS MSDS Sheet
Supplier, Manufacturer, Exporter of 2-Iodobenzoic Acid, Muby Chemicals of Mubychem Group, established in 1976, is the original manufacturers of Specialty Chemicals, Pharmaceutical Excipient, Fragrance Food & Flavor chemicals, Reagent Grade Chemicals, Shale Gas Fracturing Chemicals in India. Mubychem Group has several manufacturing facilities spread across Western India and world wide contacts and toll manufacturers. We are exporting globally to countries like USA, Canada, Europe, UAE, South Africa, Tanzania, Kenya, Egypt, Nigeria, Cameroon, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Dubai, Korea, Vietnam, Thailand, Malaysia, Indonesia, Australia, China, Germany, France, Italy, Portugal, Bangladesh, etc.
The products are offered as per required specifications and in correct shape and size in mm or meshs or microns as specified by the buyer.
The participating units have one or more accreditations like FDA - cGMP and GLP approval, ISO-9001 Certified, "REACH" Registered, ISO-14001, ISO/IEC 17025, ISO-22000, FSSC 22000, ISO 45001, Kosher Certified, Halal Certified, HACCP, FSSAI. We offer Commercial Pure & IP BP EP Ph Eur USP NF JP FCC Food Grade Analytical Reagent Grades of Chemicals
Bookmark this Web Site -- or -- Email This Page Info to a Colleague or Yourself Search our website here:
2-Iodobenzoic Acid or o-iodobenzoic acid: CAS Number: 88-67-5, EINECS EC Number: 201-850-7, Molecular Formula: C7H5IO2 or IC6H4COOH, Molecular Weight: 248.02, HS Code ---**
How big is your requirement or how small
We serve it all.Specifications, Safety Data Sheet, Manufacturing process details, Wholesale retail buy sell prices, Uses etc available on line in these pages for 2-Iodobenzoic Acid or o-iodobenzoic acid.
For SDS MSDS Sheet Click
SDS MSDS Sheet of 2-Iodobenzoic Acid Manufacturers2-Iodobenzoic Acid
Pure Suppliers
2-Iodobenzoic acid or o-iodobenzoic acid, is an organic compound with the formula IC6H4COOH. 2-Iodobenzoic acid (or o-iodobenzoic acid) is commonly used as a precursor for the synthesis of 2-Iodoxybenzoic acid (IBX) and Dess-Martin peridinane, which are used as mild oxidants. It is also used in Suziki reaction.
Specifications of 2-Iodobenzoic Acid:
CAS number: 88-67-5
Molecular formula: 2-IC6H4CO2H
Appearance: White crystal or powder.
Melting point: 159C to 164C.
Relative density: 2.25
Solubility in water: Sparingly soluble.
Appearance: White to Pale Yellow Powder.
Assay: 98.0% minimum.
Water: 0.5% maximum
Solubility (Turbidity) C=5%, ethanol: Clear to Slightly Hazy.
Appearance of solution: Colorless to light yellow or light pink.We manufacture and supply iodine chemicals or derivatives a under:
Iodoquinol or Diiodohydroxyquinoline
5-Iodoanthranilic acid or 2-Amino-5-Iodobenzoic acid
Methyltriphenylphosphonium Iodide
Manufacturers:
MUBY CHEMICALS
Ambernath Mumbai, Ankleshwar Gujarat, India
TEL: (OFFICE) +912223770100, +912223726950
Current Date Time in India GMT+5:30e-mail: info@mubychem.com
USA, Canada, Mexico and other American
neighbouring buyers may
e-mail: us@mubychem.com
Call toll-free 1-877-682-9243 (1-877-MUBYCHEM)
Copyright and Usual Disclaimer is Applicable.
Last 28 April, 2024
Exporters to USA Canada UAE Europe South Africa Tanzania Kenya Uganda Egypt Nigeria Turkey Mexico Brazil Argentina Chile Dubai etc.
Global or International Suppliers, Exporters, Importers, Manufacturers
I shall pass through this world, but once. If therefore, there is any good that I can do, or if there is any favor that I can show to a fellow human being, let me do it now. Let me not defer or neglect it. For I shall not tread this way again
2-Iodobenzoic Acid SDS, Safety Data Sheet
MSDS Sheet, Material Safety Data Sheet 24-Oct-201. Product Identification
Product Name & Other Names: 2-Iodobenzoic Acid or o-iodobenzoic acid.
CAS No.: 88-67-5
EINECS EC Number: 201-850-7
Molecular Weight: 248.02
Chemical Formula: C7H5IO2 or IC6H4COOH
Relevant uses and uses advised against (if any): Industrial Manufacturing.
Suppliers: As per letterhead.2. Hazards Identification
GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008Acute toxicity, Oral (Category 4), H302
Skin irritation (Category 2), H315
Serious eye damage (Category 1), H318
Specific target organ toxicity - single exposure (Category 3), H335Labeling according GHS & Regulation (EC) No 1272/2008
GHS Label Elements
CorrosiveSignal Words: Danger
Hazard statements:
H302: Harmful if swallowed.
H315: Causes skin irritation.
H318: Causes serious eye damage.
H335: May cause respiratory irritation.Precautionary statements:
P264: Wash … thoroughly after handling.
P270: Do not eat, drink or smoke when using this product.
P280: Wear protective gloves/protective clothing/eye protection/face protection.
P330: Rinse mouth.
P362: Take off contaminated clothing and wash before reuse.
P301+312: IF SWALLOWED: Call a POISON CENTER or doctor/physician if you feel unwell.
P302+352: IF ON SKIN: Wash with soap and water.
P332+313: If skin irritation occurs: Get medical advice/attention.
P305+351+338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do – continue rinsing.
P337+313: If eye irritation persists get medical advice/attention.
P501: Dispose of contents/container to authorized agents only.Classification according to EU Directives 67/548/EEC or 1999/45/EC:
Hazard Symbol:
Xn Harmful.
C Corrosive.
Risk Phrase:
R22 Harmful if swallowed.
R37/38 Irritating to respiratory system and skin.
R41 Risk of serious damage to eyes.3. Composition/Information on Ingredients
Product Name & Other Names: 2-Iodobenzoic Acid or o-iodobenzoic acid.
CAS No.: 88-67-5
EINECS EC Number: 201-850-74. First Aid Measures
Always seek medical attention after first aid measures are provided.
Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Ingestion: Never give anything by mouth to an unconscious person. Get medical attention.
Skin Contact: Wipe off excess material from skin then immediately flush skin with plenty of water for at least 15 minutes. Remove contaminated clothing and shoes. Get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.
Eye Contact: Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Get medical attention immediately.
Notes to Physician: Treat symptomatically.5. Fire Fighting Measures
Flammability of the Product: Non-flammable. However it will burn at high temperature.
Products of Combustion: Hydrogen iodide, Iodine, Oxides of carbon and fumes.
Explosion: Not an Explosive item.
Fire Extinguishing Media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Use any means suitable for extinguishing surrounding fire.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures or when moistened under fire conditions, it may produce toxic or irritating fumes. On decomposition it may emit hydrogen iodide. Containers may explode on heating.6. Accidental Release Measures
Personal precautions, protective equipment, and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment Cleanup procedures and Storage:
Small Spill: Avoid dust/mist formation. Avoid breathing dust. Ensure adequate ventilation. Use appropriate tools to put the spilled solid in a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and dispose of according to local and regional authority requirements.
Large Spill: Do not inhale dust, vapors, mist, or gas. Avoid dust formation. Contain spilled material. Cover with an inert, non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite). Use a shovel to put the material into a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and allow to evacuate as per law.7. Handling and Storage
Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid contact with skin and eyes. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like strong oxidizing agents and strong bases.8. Exposure Controls/Personal Protection
Airborne Exposure Limits: USA ACGIH, ACGIH TWA (ppm): 0.01 ppm Inhalable fraction
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice. Wash hands after handling.9. Physical and Chemical Properties
Appearance: White to brownish crystal or powder.
Odor: Not available.
Odor threshold: Not available.
pH: Not available.
Relative density: about 2.25
Melting Point: 159C to 164C.
Initial boiling point and boiling range: Not available.
Flash point: Not available.
Auto-ignition temperature: Not available.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor pressure: Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility: Sparingly soluble in water.
Viscosity: Not available.
Molecular Weight: 248.02
Chemical Formula: C7H5IO2 or IC6H4COOH10. Stability and Reactivity
Stability: Stable under ordinary conditions of use and storage.
Hazardous Decomposition Products: It emits toxic Hydrogen iodide, Iodine, Oxides of carbon and fumes.
Hazardous Polymerization: Will not occur.
Incompatibilities: Strong oxidizing agents and strong bases.
Conditions to Avoid: Incompatibles heat.11. Toxicological Information
Toxicity data
LD50 Oral - Mouse - 1500 mg/kg
Carcinogenic Effects: Not a reported carcinogen by IARC NTP ACGIH OSHA.
Mutagenic Effects: No information available.
Teratogenic Effects: No information available.
Developmental Toxicity: Not available.12. Ecological Information
Toxicity to fish: No information available.
Environmental Fate: Not classified as environmentally hazardous.
Persistence and Degradability: Persistence is unlikely based on information available.
Mobility: Will likely be mobile in the environment due to its water solubility.
Results of PBT and vPvB assessment: No information available.13. Disposal Considerations
Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Processing use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state, and local requirements.
14. Transport Information
DOT USA, TDG Canada & ADR/RID Europe: Not regulated.
IMDG/IMO & IATA: Not regulated.15. Regulatory Information
USA:
SARA 302 Components: No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SARA 313 Components: No chemicals in this material are subject to the reporting requirements.
SARA 311/312 Hazards: Immediate (acute) health hazard Delayed (chronic) health hazard.
California Prop.65: Not Listed.16. Other Information
European Labeling in Accordance with EC Directives:
Classification according to EU Directives 67/548/EEC or 1999/45/EC:
H302: Harmful if swallowed.
H315: Causes skin irritation.
H318: Causes serious eye damage.
H335: May cause respiratory irritation.
Hazard Symbol:
Xn Harmful.
C Corrosive.
Risk Phrase:
R22 Harmful if swallowed.
R37/38 Irritating to respiratory system and skin.
R41 Risk of serious damage to eyes.Disclaimer:
**************************
Our company provides this MSDS sheet in good faith but makes no representation as to its comprehensiveness or accuracy. This SDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. The above information has been compiled from various sources and has the possibility of discrepancy and being out-dated information. Individuals receiving the information must exercise their independent judgment and do further search in determining its appropriateness for a particular purpose. In no case shall our company be liable to loss or damages by the product user.
**************************