Supplier, Manufacturer, Exporter of Ammonium Carbonate, Muby Chemicals of Mubychem Group, established in 1976, is the original manufacturers of Specialty Chemicals, Pharmaceutical Excipient, Fragrance Food & Flavor chemicals, Reagent Grade Chemicals, Shale Gas Fracturing Chemicals in India. Mubychem Group has several manufacturing facilities spread across Western India and world wide contacts and toll manufacturers. We are exporting globally to countries like USA, Canada, Europe, UAE, South Africa, Tanzania, Kenya, Egypt, Nigeria, Cameroon, Uganda, Turkey, Mexico, Brazil, Chile, Peru, Argentina, Dubai, Korea, Vietnam, Thailand, Malaysia, Indonesia, Australia, China, Germany, France, Italy, Portugal, Bangladesh, etc.
The products are offered as per required specifications and in correct shape and size in mm or meshs or microns as specified by the buyer.
The participating units have one or more accreditations like FDA - cGMP and GLP approval, ISO-9001 Certified, "REACH" Registered, ISO-14001, ISO/IEC 17025, ISO-22000, FSSC 22000, ISO 45001, Kosher Certified, Halal Certified, HACCP, FSSAI. We offer Commercial Pure & IP BP EP Ph Eur USP NF JP FCC Food Grade Analytical Reagent Grades of Chemicals
Bookmark this Web Site -- or -- Email This Page Info to a Colleague or Yourself Search our website here:
Ammonium Carbonate CAS Number 8000-73-5, EINECS EC Number --, HS Code ---**; Molecular Weight 157.13, Molecular Formula: C2H11N3O5
How big is your requirement or how small
We serve it all.Specifications, Safety Data Sheet, Manufacturing process details, Wholesale retail prices, Uses etc available on these pages for Ammonium Carbonate.
For MSDS Sheet Click
MSDS Sheet of Ammonium Carbonate ManufacturersSpanish Fabricantes de carbonato de amonio
Portuguese Carbonato de amônio fabricantes
Ammonium Carbonate
Commercial USP Pure Analytical Reagent Grade Suppliers
Ammonium carbonate is a salt that readily degrades to gaseous ammonia and carbon dioxide upon heating, it is used as a leavening agent and also as smelling salt. It is also known as baker's ammonia and was a predecessor to the more modern leavening agents baking soda and baking powder. Ammonium carbonate decomposes at standard temperature and pressure through two pathways. It has a short shelf life.
Ammonium carbonate CAS 506-87-6 Einecs EC 233-786-0 is a salt with the chemical formula (NH4)2CO3 and molecular weight 96.09. Since it readily degrades to gaseous ammonia and carbon dioxide upon heating, it is used as a leavening agent and also as smelling salt. It is also known as baker's ammonia. Pure Ammonium carbonate is distinctly different from Ammonium Carbonate reagent, USP and FCC grades which consists of ammonium bicarbonate (NH 4HCO3) and ammonium carbamate (NH2COONH4) in varying proportions.
General Specifications and Properties of ammonium Carbonate:
Appearance: White powder.
Ammonia content: 35%. It is an unstable compound and the assay as NH3 may go down.
Relative density: 1.5
Melting point: 58C.
Solubility: Soluble in water.
Ammonium Carbonate USP
Carbonic acid, monoammonium salt, mixture with ammonium carbamate.
Monoammonium carbonate mixture with ammonium carbamate [8000-73-5].Ammonium Carbonate consists of ammonium bicarbonate (NH 4HCO3) and ammonium carbamate (NH2COONH4) in varying proportions. It yields not less than 30.0 percent and not more than 34.0 percent of NH3.
Packaging and storage: Preserve in tight, light-resistant containers, at a temperature not above 30C.
Identification: When heated, it is volatilized without charring, and the vapor is alkaline to moistened litmus paper. A solution (1 in 20) effervesces with acids.
Residue on ignition: not more than 0.1%.
Chloride: Maximum 0.0035%.
Sulfate: A 2.0-g portion shows no more sulfate than corresponds to 0.10 mL of 0.020 N sulfuric acid (0.005%).
Heavy metals: the limit is 0.001%.
Assay: Place in a weighing bottle about 10 mL of water, tare the bottle and its contents, add about 2 g of Ammonium Carbonate, and weigh accurately. Transfer the contents of the bottle to a 250-mL flask, add 50.0 mL of 1 N sulfuric acid VS, and, when solution has been effected, add methyl orange, and titrate the excess acid with 1 N sodium hydroxide. Perform a blank determination. Each mL of 1 N sulfuric acid is equivalent to 17.03 mg of NH3.
Ammonium Carbonate FCC Food Grade
INS: 503(i); CAS: [10361-29-2]
DESCRIPTION
Ammonium Carbonate occurs as a white powder or as hard, white or translucent masses. It consists of ammonium bicarbonate (NH4HCO3) and ammonium carbamate (NH2·COONH4) in varying proportions. On exposure to air it becomes opaque and is finally converted into porous lumps or a white powder of ammonium bicarbonate because of the loss of ammonia and carbon dioxide. One gram dissolves slowly in about 4 mL of water. Its solutions are alkaline to litmus.
Function: Buffer; leavening agent; neutralizing agent.REQUIREMENTS
Identification: When heated, a sample volatilizes without charring, and the vapor is alkaline to moistened litmus paper. A 1:20 aqueous solution effervesces when an acid is added.
Assay: Not less than 30.0% and not more than 34.0% of NH3.
Chloride: Not more than 0.003%.
Lead: Not more than 3 mg/kg.
Nonvolatile Residue: Not more than 0.05%.
Sulfur Compounds (as SO4): Not more than 0.005%.
Ammonium Carbonate Analytical Reagent Grade
CAS Number 8000-73-5
NOTE. This product is a mixture of variable proportions of ammonium bicarbonate and ammonium carbamate.
REQUIREMENTS
Assay ≥30.0% NH3
MAXIMUM ALLOWABLE
Insoluble matter 0.005% Nonvolatile matter 0.01% Chloride (Cl) 5 ppm Sulfur compounds (as SO4) 0.002% Heavy metals (as Pb) 5 ppm Iron (Fe) 5 ppm For Original Monographs of IP Indian Pharmacopoeia BP British Pharmacopoeia USP US Pharmacopoeia FCC Food Grade product, please check with the respective eb-pages or books.
We manufacture and supply as under:
Ammonium Tartrate Dibasic or Diammonium Tartrate
Murexide or Ammonium Purpurate
Sodium Diethyldithiocarbamate Trihydrate
Manufacturers:
MUBY CHEMICALS
Ambernath Mumbai, Ankleshwar Gujarat, India
TEL: (OFFICE) +912223770100, +912223726950
Current Date Time in India GMT+5:30e-mail: info@mubychem.com
USA, Canada, Mexico and other American
neighbouring buyers may
e-mail: us@mubychem.com
Call toll-free 1-877-682-9243 (1-877-MUBYCHEM)
Copyright and Usual Disclaimer is Applicable.
Last : 1 December, 2024
Exporters to USA Canada UAE Europe South Africa Tanzania Kenya Uganda Egypt Nigeria Turkey Mexico Brazil Argentina Chile Dubai etc.
Global or International Suppliers, Exporters, Importers, Manufacturers
I shall pass through this world, but once. If therefore, there is any good that I can do, or if there is any favor that I can show to a fellow human being, let me do it now. Let me not defer or neglect it. For I shall not tread this way again
Ammonium Carbonate SDS, Safety Data Sheet
MSDS Sheet, Material Safety Data Sheet 30-Sep-201. Product Identification
Product Name & Other Names: Ammonium Carbonate
CAS No.: 8000-73-5 or 10361-29-2 and 506-87-6 for Pure grade (NH4)2CO3
EINECS EC Number: 233-786-0
Relevant uses and uses advised against (if any): Industrial Manufacturing.
Suppliers: As per letterhead.2.Hazards Identification
GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008:Acute toxicity, Oral Category 4
Hazardous to the aquatic environment, acute hazard Category 3Labeling according to GHS & Regulation (EC) No 1272/2008
GHS Label Elements
IrritantSignal Words: Warning
Hazard statements:
H302: Harmful if swallowed.
H315: Causes skin irritation.
H318: Causes serious eye damage.
H402: Harmful to aquatic life.Precautionary statements:
P264 Wash skin thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P273 Avoid release to the environment.
P280: Wear protective gloves/protective clothing/eye protection/face protection.
P314: Get Medical advice/attention if you feel unwell.
P362: Take off contaminated clothing and wash before reuse.
P301+P312: IF SWALLOWED: Call a POISON CENTER or doctor/physician if you feel unwell.
P302+352: IF ON SKIN: Wash with soap and water.
P332+313: If skin irritation occurs: Get medical advice/attention.
P305+351+338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do – continue rinsing.
P330: Rinse mouth.
P501: Dispose of contents/ container to an approved waste disposal plant.Classification according to EU Directives 67/548/EEC or 1999/45/EC:
Hazard Symbol:
Xn: Harmful
Xi: Irritant,
Risk Phrase:
R22: Harmful if swallowed.
R38 Irritating to skin
R41 Risk of serious damage to eyes3. Composition/Information on Ingredients
Product Name & Other Names: Ammonium Carbonate
CAS No.: 8000-73-5 or 10361-29-2 and 506-87-6 for Pure grade (NH4)2CO3
EINECS EC Number: 233-786-04. First Aid Measures
Always seek medical attention after first aid measures are provided.
Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Ingestion: Do not induce vomiting unless as directed by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.
Skin Contact: Immediately flush skin with plenty of water for at least 15 minutes. Remove contaminated clothing and shoes. Get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.
Eye Contact: Check for and remove any contact lenses. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Cold water may be used. Get medical attention.5. Fire Fighting Measures
Fire: Not considered to be a fire hazard. At fire temperatures it begins to corrode metals and may dissociate into ammonia, oxides of nitrogen and carbon dioxide.
Explosion: It is not considered to be an explosion hazard.
Fire Extinguishing Media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Water spray may be used to keep fire exposed containers cool.
Special Information In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures under fire conditions, it may produce toxic or irritating fumes.6. Accidental Release Measures
Personal precautions, protective equipment, and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Ensure adequate ventilation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment Cleanup procedures and Storage:
Small Spill: Use appropriate tools to put the spilled solid in a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and dispose of according to local and regional authority requirements.
Large Spill: Contain spilled material. Cover with an inert, non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite). Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist, or gas. Ensure adequate ventilation. Avoid breathing dust. Use a shovel to put the material into a convenient waste disposal container. Do not let product enter drains. Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal.7. Handling and Storage
Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Do not leave the material container open. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid contact with skin and eyes. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like concentrated acids, strong bases, oxidizing agents. Store away from sources of heat, moisture.8. Exposure Controls/Personal Protection
Airborne Exposure Limits: Not established
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area. Please refer to the ACGIH document, Industrial Ventilation, A Manual of Recommended Practices, most recent edition, for details.
Personal Respirators (NIOSH Approved): If the exposure limit is exceeded and engineering controls are not feasible, a half face piece particulate respirator (NIOSH type N95 or better filters) may be worn for up to ten times the exposure limit or the maximum use concentration specified by the appropriate regulatory agency or respirator supplier, whichever is lowest. A full-face piece particulate respirator (NIOSH type N100 filters) may be worn up to 50 times the exposure limit, or the maximum use concentration specified by the appropriate regulatory agency, or respirator supplier, whichever is lowest. If oil particles (e.g. lubricants, cutting fluids, glycerin, etc.) are present, use a NIOSH type R or P filter. For emergencies or instances where the exposure levels are not known, use a full-face piece positive-pressure, air-supplied respirator.
Skin Protection: Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice. Wash hands after handling.9. Physical and Chemical Properties
Appearance: White solid.
Odor: Strong ammonia odor.
Odor threshold: Not available.
pH: >9
Relative density: Not available.
Melting Point: 58C
Initial boiling point and boiling range: Not available.
Flash point: Not available.
Auto-ignition temperature: Not available.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor Pressure (mm Hg): 1.0 @ 160C (320F).
Vapor Density (Air=1): 1.9
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility: Soluble in water.
Viscosity: Not available.10. Stability and Reactivity
Stability: Stable under ordinary conditions of use and storage.
Hazardous Decomposition Products: Involvement in a fire causes decomposition to form carbon dioxide and ammonia.
Hazardous Polymerization: Will not occur.
Incompatibilities: Concentrated acids, strong bases, oxidizing agents, heat.11. Toxicological Information
Acute toxicity:
LD50 Oral - Rat - male and female: 2.150 mg/kg
LD50 Oral - Rat - female: 1.800 mg/kg
LD50 Dermal - Rat : > 2.000 mg/kg
LD50 Intravenous - Mouse: 96 mg/kg
Carcinogenicity: The product is not classed as carcinogen by IARC, ACGIH, NTP, OSHA.
Mutagenic Effects: Not available.
Developmental Toxicity: Not available.
Reproductive Effects: No information available.12. Ecological Information
Toxicity to fish: LC50 (96 h) 61 mg/l, Oncorhynchus mykiss (Flow through.) Literature.
Toxicity to daphnia and other aquatic invertebrates: EC50 (48 h) 63.7 mg/l, Daphnia magna.
Persistence and Degradability: Degradable.
Mobility: Mobile due to water solubility.
Bioaccumulation/ Accumulation: Not likely to accumulate.
Results of PBT and vPvB assessment: This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.13. Disposal Considerations
Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Processing use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused material in accordance with legal requirements.
14. Transport Information
DOT USA ADR/RID Europe:
Not Regulated
IMDG:
Not dangerous goods
IATA:
Not dangerous goods15. Regulatory Information
USA:
SARA 302: No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SARA 313: This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minimis) reporting levels established by SARA Title III, Section 313.
SARA 311/312 Hazards: Acute Health Hazard
California Prop. 65 Components: This product does not contain any chemicals known to State of California to cause cancer, birth defects, or any other reproductive harm.16. Other Information
European Labeling in Accordance with EC Directives:
H302: Harmful if swallowed.
H315: Causes skin irritation.
H319: Causes serious eye irritation.
H402: Harmful to aquatic life.Classification according to EU Directives 67/548/EEC or 1999/45/EC:
Hazard Symbols:
Xn: Harmful
Xi: Irritant,
Risk Phrases:
R22: Harmful if swallowed.
R36/38 Irritating to eyes and skin.Disclaimer:
*************************
Our company provides this SDS information sheet contained herein in good faith but makes no representation as to its comprehensiveness or accuracy. This MSDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a particular purpose.
*************************