Copper Lactate Gluconate or Copper Lacto Gluconate Manufacturers, with SDS GHS MSDS Sheet

Supplier, Manufacturer, Exporter of Copper Lactate Gluconate or Copper Lacto Gluconate Muby Chemicals of Mubychem Group, established in 1976, is the original manufacturers of Specialty Chemicals, Pharmaceutical Excipient, Fragrance Food & Flavor chemicals, Reagent Grade Chemicals, Shale Gas Fracturing Chemicals in India. Mubychem Group has several manufacturing facilities spread across Western India and world wide contacts and toll manufacturers. We are exporting globally to countries like USA, Canada, Europe, UAE, South Africa, Tanzania, Kenya, Egypt, Nigeria, Cameroon, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Dubai, Korea, Vietnam, Thailand, Malaysia, Indonesia, Australia, China, Germany, France, Italy, Portugal, Bangladesh, etc.

The products are offered as per required specifications and in correct shape and size in mm or meshs or microns as specified by the buyer.

The participating units have one or more accreditations like FDA - cGMP and GLP approval, ISO-9001 Certified, "REACH" Registered, ISO-14001, ISO/IEC 17025, ISO-22000, FSSC 22000, ISO 45001, Kosher Certified, Halal Certified, HACCP, FSSAI. We offer Commercial Pure & IP BP EP Ph Eur USP NF JP FCC Food Grade Analytical Reagent Grades of Chemicals
ISO9001 ISO IEC 17025 ISO14001 ISO 45001 ISO 22000 HACCP FSSC22000 HACCP GMP Good Laboratory fssai HACCP halal jkkosher allergen free Gluten Free Reach

Bookmark this Web Site -- or -- Email This Page Info to a Colleague or Yourself

Search our website here:

Home --------- Contact

Chemical Products

Export to USA UAE Europe Africa Tanzania Kenya Egypt Turkey Jumbo Packing; Exports to USA UAE Europe Africa Tanzania Kenya Uganda Egypt Turkey Brazil Chile Argentina Dubai etc. Packing Palletized and Shrink Wrapped; 25kg or 50kg or 55 lbs HDPE laminated bags with an extra HMHDP liner Drum Packing for better transportation Drum Packing & Palletized Liquid Chemical Export Import Air Freighting

Copper Lactate Gluconate or Copper Lacto Gluconate: CAS Number: Copper Lactate : 16039-52-4 and Copper Gluconate: 527-09-03, EINECS EC Number: yyyyy, Molecular Formula: Copper Lactate: C6H10O6Cu and Copper Gluconate: C12H22O14Cu, Molecular Weight: Copper Lactate: 241.70 and Copper Gluconate: 453.84, HS Code ---**

How big is your requirement or how small
We serve it all.

Specifications, Safety Data Sheet, Manufacturing process details, Wholesale retail buy sell prices, Uses etc available on line in these pages for Copper Lactate Gluconate or Copper Lacto Gluconate.

For SDS MSDS Sheet Click
SDS MSDS Sheet of Copper Lactate Gluconate or Copper Lacto Gluconate Manufacturers

Copper Lactate Gluconate
Copper Lacto Gluconate Pure Suppliers
Copper Lactate Gluconate

Copper Lactate Gluconate or Copper Lacto Gluconate has copper lactate (C6H10CuO6) and copper gluconate (C12H22CuO14) with molecular weights 241.69 g/mol and 453.84 g/mol respectively. Copper maintains proper functioning of cuproenzymes (Cu dependent enzymes) along with maintaining skin strength and blood vessels.

Specifications of Copper Lactate Gluconate or Copper Lacto Gluconate:
Formula: Copper Lactate: C6H10O6Cu and Copper Gluconate: C12H22O14Cu
Molecular Weight: Copper Lactate: 241.70 and Copper Gluconate: 453.84
CAS Number: Copper Lactate : 16039-52-4 and Copper Gluconate: 527-09-03
Appearance: Light blue or bluish green powder.
Solubility of 10% solution in water: Soluble.
Arsenic: 3 ppm maximum.
Lead: 5 ppm maximum.
Loss on drying (@ 105C for 2 hrs) 10% maximum.
Assay: Copper content (As is basis) 18.0 % - 21.0%
Total bacterial count: 1000 cfu/g maximum.
Yeast and mold: 100 cfu/g maximum.
E. coli:  To be absent.
Salmonella: To be absent.
Pseudomonas aeruginosa: To be absent.
Staphylococcus aureus: To be absent.

We manufacture and supply various Gluconic Acid salts and Gluconates:

Boron Gluconate

Calcium Borogluconate

Calcium Gluconate

Calcium Lactate Gluconate

Calcium Magnesium Lactate Gluconate

Cobalt Gluconate

Copper Gluconate

Copper Lactate Gluconate

Ferrous Gluconate

Ferrous Lactate Gluconate

Gluconic Acid

Magnesium Borogluconate

Magnesium Gluconate

Magnesium Lactate Gluconate

Manganese Gluconate

Manganese Lactate Gluconate

Nickel Gluconate

Potassium Gluconate

Sodium Gluconate

Sodium Stibogluconate

Strontium Gluconate

Zinc Gluconate.

We manufacture and supply various Lactic Acid salts and Lactates:

Ammonium Lactate Solution

Calcium Lactate

Calcium Lactate Gluconate

Calcium Magnesium Lactate Gluconate

Copper Lactate Gluconate

Lactic Acid

Magnesium Lactate Dihydrate

Magnesium Lactate Gluconate

Manganese Lactate

Sodium Lactate

Zinc Lactate Gluconate.

Manufacturers:

MUBY CHEMICALS
Ambernath Mumbai, Ankleshwar Gujarat, India
TEL: (OFFICE) +912223770100, +912223726950
Current Date Time in India GMT+5:30

e-mail: info@mubychem.com

USA, Canada, Mexico and other American
neighbouring buyers may
e-mail: us@mubychem.com
Call toll-free 1-877-682-9243 (1-877-MUBYCHEM)

Manufacturers india
Copyright and Usual Disclaimer is Applicable.
Last 20 April, 2024

List of All the IP, BP, EP, Ph Eur, USP NF, JP, FCC Food, Analytical Reagent Grades of Chemicals
Best Seller Fast Moving IP, BP, EP, Ph Eur, USP NF, JP, FCC Food, Analytical Reagent Grades of Chemicals Ex-stock Items
Aluminum Chloride Hexahydrate Aluminium Potassium Sulphate
Ammonium Bicarbonate Ammonium Carbonate
Ammonium Chloride Ammonium Persulfate
Borax; Sodium Borate Boric Acid
Calcium Chloride Calcium Saccharate
Calcium Sulfate Carbamide Peroxide
Chromic Chloride Cupric or Copper Chloride
Ferric Chloride Hexahydrate Fumaric Acid
Glacial Acetic Acid Lactobionic Acid
Magnesium Chloride Magnesium Sulfate
Manganese Chloride Manganese Sulfate
Potassium Bromide Potassium Chloride
Potassium Hydroxide Pellets Potassium Nitrate
Propylene Carbonate Potassium Monopersulfate
Selenious acid Sodium Acetate
Sodium Bromate Sodium Diacetate
Sodium Formaldehyde Bisulfite Sodium Lactobionate
Sodium Thiosulfate Zinc Chloride

Exporter & Importer By Air Exports Exporters & Improters Copper Lactate Gluconate Manufacturers

Exporters to USA Canada UAE Europe South Africa Tanzania Kenya Uganda Egypt Nigeria Turkey Mexico Brazil Argentina Chile Dubai etc.

Global or International Suppliers, Exporters, Importers, Manufacturers

I shall pass through this world, but once. If therefore, there is any good that I can do, or if there is any favor that I can show to a fellow human being, let me do it now. Let me not defer or neglect it. For I shall not tread this way again

Copper Lactate Gluconate SDS, Safety Data Sheet
MSDS Sheet, Material Safety Data Sheet
10-Oct-20

Section 1: Chemical Product and Company Identification

Product Name & Other Names: Copper Lactate Gluconate or Copper Lacto Gluconate.
CAS Number
: Copper Lactate : 16039-52-4 and Copper Gluconate: 527-09-03
EINECS EC Code: --
Chemical Formula: Copper Lactate: C6H10O6Cu and Copper Gluconate: C12H22O14Cu
Molecular Weight: Copper Lactate: 241.70 and Copper Gluconate: 453.84
Relevant uses and uses advised against (if any): Industrial Manufacturing.
Suppliers: As per letterhead.

Section 2: Hazards Identification

GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008

Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.
This substance is not classified as dangerous according to Directive 67/548/EEC.

Labeling according GHS & Regulation (EC) No 1272/2008

GHS Label Elements
NONE

Signal Word: None

Hazards not otherwise classified (HNOC):
May causes mild skin irritation.
May causes mild eye irritation.

Precautionary statements:
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P262: Do not get in eyes, on skin, or on clothing.
P281: Use personal protective equipment as required.
P302+P352: IF ON SKIN: Wash with plenty of soap and water.
P303+P361+P353: IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
P304 + P340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337+313: If eye irritation persists get medical advice/attention.

Section 3: Composition and Information on Ingredients

Product Name & Other Names: Copper Lactate Gluconate or Copper Lacto Gluconate.
CAS Number
: Copper Lactate: 16039-52-4 and Copper Gluconate: 527-09-03
EINECS EC Code: --

Section 4: First Aid Measures

Always seek medical advice after the first aid treatment.

Skin: Rinse with water. Soap may be used. Seek Medical Aid.
Eyes: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally. Seek Medical Aid.
Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Ingestion: If swallowed, induce vomiting immediately after giving two glasses of water. Never give anything by mouth to an unconscious person.
Notes to Physician: Treat symptomatically.

Section 5: Fire and Explosion Data

Flammability of the Product: Non-flammable.
Flash Points: Not applicable.
Products of Combustion: Copper oxide, Fumes and Oxides of carbon.
Fire Fighting Media and Instructions: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures under fire conditions, it may produce toxic or irritating fumes.

Section 6: Accidental Release Measures

Personal precautions, protective equipment, and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment Cleanup procedures and Storage:
Small Spill: Use appropriate tools to put the spilled solid in a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and dispose of according to legal requirements.
Large Spill: Do not inhale dust, vapors, mist, or gas. Avoid dust formation. Contain spilled material. Cover with an inert, non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite). Use a shovel to put the material into a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and allow to evacuate as per law.

Section 7: Handling and Storage

Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid contact with skin and eyes. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like strong oxidizing agents and acids.

Section 8: Exposure Controls/Personal Protection

Exposure Limits:
TWA: 1 (mg(Cu)/m3) [United States]
TWA: 1 (mg(Cu)/m3) from NIOSH [United States]
TWA: 1 (mg(Cu)/m3) [Canada]
Engineering Controls: Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. If user operations generate dust, fume, or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice. Wash hands after handling.

Section 9: Physical and Chemical Properties

Physical state and appearance: Light blue or bluish green powder.
Odor: Not available.
Odor threshold: Not available.
pH: Not available.
Relative density: Not available.
Melting point/freezing point: Not available.
Initial boiling point and boiling range: Not available.
Flash point: Not available.
Auto-ignition temperature: Not available.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor pressure: Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility: Soluble in water.
Viscosity: Not available.
Chemical Formula: Copper Lactate: C6H10O6Cu and Copper Gluconate: C12H22O14Cu
Molecular Weight: Copper Lactate: 241.70 and Copper Gluconate: 453.84

Section 10: Stability and Reactivity Data

Stability: It is stable.
Conditions of instability: Incompatible materials
Incompatibility with various substances: Heat, light, strong oxidizing agents.
Hazardous decomposition products: Carbon oxides & Copper oxides are expected.
Polymerization: Will not occur.

Section 11: Toxicological Information

Toxicity to Animals: Not available.
Carcinogenicity: Not reported as carcinogen by any agency.
Reproductive Toxicity: No information available.
Developmental Effects: No information available.
Teratogenicity: No information available.

Section 12: Ecological Information

Ecotoxicity: The product may be considered harmful to aquatic organisms. Not dangerous for the ozone layer.
Persistence and Degradability: No information available.
Bioaccumulation/ Accumulation: No information available.
Mobility: No information available.
Results of PBT and vPvB assessment: No information available.

Section 13: Disposal Considerations

Waste Disposal: Waste must be disposed of in accordance with federal, state, and local environmental control regulations.

Section 14: Transport Information

DOT USA: Not dangerous goods
IMDG: Not dangerous goods
IATA: Not dangerous goods
ADR/RID Europe: Not dangerous goods.

Section 15: Other Regulatory Information

USA Federal and State Regulations:
USA:
California Proposition 65: Not Listed
SARA 311: No SARA Hazards
SARA 312: No SARA Hazards

Section 16 - Additional Information

Disclaimer:
**************************
Our company provides this MSDS sheet in good faith but makes no representation as to its comprehensiveness or accuracy. This SDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. The above information has been compiled from various sources and has the possibility of discrepancy and being out-dated information. Individuals receiving the information must exercise their independent judgment and do further search in determining its appropriateness for a particular purpose. In no case shall our company be liable to loss or damages by the product user.
**************************