Cadmium Chloride Anhydrous & Hemi-pentahydrate Crystals Pure Analytical Reagent Grade Manufacturers, with SDS GHS MSDS Sheet

Supplier, Manufacturer, Exporter of Cadmium Chloride Anhydrous n Hemi-pentahydrate Crystals, Muby Chemicals of Mubychem Group, established in 1976, is the original manufacturers of Specialty Chemicals, Pharmaceutical Excipient, Fragrance Food & Flavor chemicals, Reagent Grade Chemicals, Shale Gas Fracturing Chemicals in India. Mubychem Group has several manufacturing facilities spread across Western India and world wide contacts and toll manufacturers. We are exporting globally to countries like USA, Canada, Europe, UAE, South Africa, Tanzania, Kenya, Egypt, Nigeria, Cameroon, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Dubai, Korea, Vietnam, Thailand, Malaysia, Indonesia, Australia, China, Germany, France, Italy, Portugal, Bangladesh, etc.

The products are offered as per required specifications and in correct shape and size in mm or meshs or microns as specified by the buyer.

The participating units have one or more accreditations like FDA - cGMP and GLP approval, ISO-9001 Certified, "REACH" Registered, ISO-14001, ISO/IEC 17025, ISO-22000, FSSC 22000, ISO 45001, Kosher Certified, Halal Certified, HACCP, FSSAI. We offer Commercial Pure & IP BP EP Ph Eur USP NF JP FCC Food Grade Analytical Reagent Grades of Chemicals
ISO9001 ISO IEC 17025 ISO14001 ISO 45001 ISO 22000 HACCP FSSC22000 HACCP GMP Good Laboratory fssai HACCP halal jkkosher allergen free Gluten Free Reach

Bookmark this Web Site -- or -- Email This Page Info to a Colleague or Yourself

Search our website here:

Home --------- Contact

Chemical Products

Export to USA UAE Europe Africa Tanzania Kenya Egypt Turkey Jumbo Packing; Exports to USA UAE Europe Africa Tanzania Kenya Uganda Egypt Turkey Brazil Chile Argentina Dubai etc. Packing Palletized and Shrink Wrapped; 25kg or 50kg or 55 lbs HDPE laminated bags with an extra HMHDP liner Drum Packing for better transportation Drum Packing & Palletized Liquid Chemical Export Import Air Freighting

Cadmium Chloride Anhydrous: CAS Number: 10108-64-2, EINECS EC Number: 233-296-7, Molecular Formula: CdCl2, Molecular Weight: 183.32, HS Code ---**
Cadmium Chloride Hemipentahydrate: CAS Number: 7790-78-5, EINECS EC Number: 233-296-7, Molecular Formula: 233-296-7, Molecular Weight: 228.35, HS Code ---**

How big is your requirement or how small
We serve it all.

Specifications, Safety Data Sheet, Manufacturing process details, Wholesale retail prices, Uses etc available on these pages for Cadmium Chloride Anhydrous Hemipentahydrate.

For SDS MSDS Sheet Click
SDS MSDS Sheet of Cadmium Chloride Anhydrous & Hemi-pentahydrate Crystals Manufacturers

Cadmium Chloride Anhydrous & Hemi-pentahydrate Crystals
Pure & Reagent Grade Suppliers
Cadmium chloride

Cadmium chloride is a white crystalline compound of cadmium and chlorine, with the formula CdCl2. It is a hygroscopic solid that is highly soluble in water and slightly soluble in alcohol.

Cadmium Chloride Crystals Hemi Pentahydrate as per Analytical Reagent Grade
CdCl2-2.5H2O
CAS No.: 7790-78-5
EC Number 233-296-7
Molecular Weight 228.35

REQUIREMENTS
Appearance: (Color) White
Appearance: (Form) Powder or Chunks
Titration with AgNO3 % CdCl2: 79.5 - 81.0 %

MAXIMUM ALLOWABLE
Calcium (Ca): 0.005% maximum
Copper: 5 ppm maximum
Lead (Pb): 0.005% maximum
Potassium (K): 0.02 % maximum
Iron: 5 ppm maximum
Sodium: 0.05 % maximum
Zinc: 0.05 % maximum
Insoluble matter: 0.005 % maximum
Nitrate and nitrite (as NO3): 0.003 % maximum
Sulfate: 0.005 % maximum
Ammonium: 0.005 % maximum


Cadmium Chloride Anhydrous as per Analytical Reagent Grade
CdCl2
CAS No.: 10108-64-2
Weight 183.32
EC Number 233-296-7

REQUIREMENTS
Assay: 99.0% CdCl2

MAXIMUM ALLOWABLE
Insoluble matter: 0.01%
Nitrate and nitrite (as NO3): 0.003%
Sulfate (SO4): 0.01%
Ammonium (NH4): 0.01%
Calcium (Ca): 0.01%
Copper (Cu): 0.001%
Lead (Pb): 0.005%
Potassium (K): 0.02%
Sodium (Na): 0.05%
Zinc (Zn): 0.05%
Iron (Fe): 0.001%

We also manufacture and supply as under:

Cadmium Acetate Dihydrate Anhydrous

Cadmium Chloride

Cadmium Nitrate

Cadmium Sulfate

Cadmium Carbonate

Cadmium Oxide

Cadmium Sulfide

Cadmium Tungstate

Cadmium Selenide

Molybdic acid Cadmium.

Manufacturers:

MUBY CHEMICALS
Ambernath Mumbai, Ankleshwar Gujarat, India
TEL: (OFFICE) +912223770100, +912223726950
Current Date Time in India GMT+5:30

e-mail: info@mubychem.com

USA, Canada, Mexico and other American
neighbouring buyers may
e-mail: us@mubychem.com
Call toll-free 1-877-682-9243 (1-877-MUBYCHEM)

Manufacturers india
Copyright and Usual Disclaimer is Applicable.
Last 15 April, 2024

List of All the IP, BP, EP, Ph Eur, USP NF, JP, FCC Food, Analytical Reagent Grades of Chemicals
Best Seller Fast Moving IP, BP, EP, Ph Eur, USP NF, JP, FCC Food, Analytical Reagent Grades of Chemicals Ex-stock Items
Aluminum Chloride Hexahydrate Aluminium Potassium Sulphate
Ammonium Bicarbonate Ammonium Carbonate
Ammonium Chloride Ammonium Persulfate
Borax; Sodium Borate Boric Acid
Calcium Chloride Calcium Saccharate
Calcium Sulfate Carbamide Peroxide
Chromic Chloride Cupric or Copper Chloride
Ferric Chloride Hexahydrate Fumaric Acid
Glacial Acetic Acid Lactobionic Acid
Magnesium Chloride Magnesium Sulfate
Manganese Chloride Manganese Sulfate
Potassium Bromide Potassium Chloride
Potassium Hydroxide Pellets Potassium Nitrate
Propylene Carbonate Potassium Monopersulfate
Selenious acid Sodium Acetate
Sodium Bromate Sodium Diacetate
Sodium Formaldehyde Bisulfite Sodium Lactobionate
Sodium Thiosulfate Zinc Chloride

Exporter & Importer By Air Exports Exporters & Improters Cadmium chloride anhydrous crystals manufacturers

Exporters to USA Canada UAE Europe South Africa Tanzania Kenya Uganda Egypt Nigeria Turkey Mexico Brazil Argentina Chile Dubai etc.

Global or International Suppliers, Exporters, Importers, Manufacturers

I shall pass through this world, but once. If therefore, there is any good that I can do, or if there is any favor that I can show to a fellow human being, let me do it now. Let me not defer or neglect it. For I shall not tread this way again

Cadmium Chloride SDS, Safety Data Sheet
MSDS Sheet, Material Safety Data Sheet
04-Oct-20

Section 1. Product Information

Product Name & Other Names: Cadmium Chloride Crystals Hemi Pentahydrate OR Cadmium Chloride Anhydrous.
Chemical Formula: CdCl2-2.5H2O OR CdCl2
Molecular Weight: 228.35 OR 183.32
CAS No.: 7790-78-5 OR 10108-64-2
EINECS EC Number: 233-296-7
Relevant uses and uses advised against (if any): Industrial Manufacturing.
Suppliers: As per letterhead.

Section 2: Hazards Identification

GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008

Acute toxicity, oral Category 3 H301
Acute toxicity, inhalation Category 1, 2, H330
Germ cell mutagenicity Category 1A, 1B, H340
Carcinogenicity Category 1A, 1B, H350
Reproductive toxicity Category 1A, 1B
Specific target organ toxicity - repeated exposure (Category 1), H372
Chronic aquatic toxicity (Category 1), H410

Labeling according GHS & Regulation (EC) No 1272/2008

GHS Label Elements
Aquatic Toxicity
Aquatic Toxicity

GHS Label Elements
Health Hazard
Health Hazard

GHS Label Elements
toxic.png
Toxic

Signal Words: Danger

Hazard statements:
H301 Toxic if swallowed.
H330 Fatal if inhaled.
H340 May cause genetic defects.
H350 May cause cancer.
H360 May damage fertility or the unborn child.
H372 Cause damage to organs through prolonged or repeated exposure.
H410 Very toxic to aquatic life with long lasting effects.

Precautionary statements:
P201: Obtain special instructions before use.
P202: Do not handle until all safety precautions have been read and understood.
P260: Do not breathe dust/fume/gas/mist/vapors/spray.
P264: Wash … thoroughly after handling.
P270: Do not eat, drink or smoke when using this product.
P271: Use only outdoors or in a well-ventilated area.
P273: Avoid release to the environment.
P280: Wear protective gloves/protective clothing/eye protection/face protection.
P284: Wear respiratory protection.
P314: Get medical advice/attention if you feel unwell.
P330: Rinse mouth.
P301+310: IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician.
P304+340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P308+313: IF exposed or concerned: Get medical advice/attention.
P391: Collect spillage.
P405: Store locked up.
P403+233: Store in a well-ventilated place. Keep container tightly closed.
P501: Dispose of contents/container in accordance with local/regional/national/international regulation.

Classification according to EU Directives 67/548/EEC or 1999/45/EC:
Hazard Symbol:
T Toxic
Xn Harmful
N Dangerous for the environment.
Risk Phrase:
R25 Toxic if swallowed.
R26 Very toxic by inhalation.
R33 Danger of cumulative effects.
R45 May cause cancer.
R46 May cause inheritable genetic damage.
R61 May cause harm to the unborn child.
R48 Danger of serious damage to health by prolonged exposure.
R50 Very toxic to aquatic organisms.
R53 May cause long-term adverse effects in the aquatic environment.

Section 3: Composition and Information on Ingredients

Product Name & Other Names: Cadmium Chloride Crystals Hemi Pentahydrate OR Cadmium Chloride Anhydrous.
CAS No.: 7790-78-5 OR 10108-64-2
EINECS EC Number: 233-296-7

Section 4. First Aid & Procedure

Always get medical attention after the first aid is over.

Ingestion: Never give anything by mouth to an unconscious person. Get medical attention.
Skin:
Immediately flush skin with plenty of water for at least 15 minutes. Remove and wash contaminated clothing and shoes before reuse. Get medical attention if irritation develops.
Eyes:
Immediately flush eyes with plenty of water for 15 minutes, occasionally lifting upper and lower eyelids. Hold eyelids apart during irrigation. Get medical attention.
Inhalation:
Remove person to fresh air. If breathing is difficult, give oxygen. If not breathing administer artificial respiration. Get medical attention.

Section 5. Fire Fighting Measures

Flash Point: N/A
Fire/Explosion:
Not considered to be a fire and explosion hazard.
Extinguishing Medium:
Water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture: Cadmium oxides & chlorine or hydrochloric acid may evolve.
Fire Fighting Instructions: Use suitable protective equipment for surrounding fire.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures under fire conditions, it may produce toxic or irritating fumes.

Section 6. Spills and Disposals

Personal precautions, protective equipment, and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment Cleanup procedures and Storage: Do not inhale dust, vapors, mist, or gas. Avoid dust formation. Contain spilled material. Cover with an inert, non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite). Use a shovel to put the material into a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and allow to evacuate as per law.

Section 7. Handling and Storage

Hygroscopic, Air sensitive, very toxic hazardous material.
Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid contact with skin and eyes. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like strong oxidizing agents.

Section 8. Exposure Controls & Personal Protection

Exposure Limits:
TWA 0.010 mg/m3, USA, ACGIH Threshold Limit Values
Engineering Controls: Use adequate exhaust ventilation to keep airborne concentrations below the allowable exposure limit.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice. Wash hands after handling.

Section 9. Physical & Chemical Data

Appearance: White solid.
Odor: Not available.
Odor threshold: Not available.
pH: Not available.
Relative density: around 3.33 for hemi-pentahydrate and 4.05 for anhydrous.
Melting Point: hemi-pentahydrate will decompose to anhydrous and 568C for anhydrous.
Initial boiling point: hemi-pentahydrate will decompose to anhydrous and 960C for anhydrous.
Flash point: Not available.
Auto-ignition temperature: Not available.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor pressure: Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility(ies): Not available.
Viscosity: Not available.
Chemical Formula: CdCl2-2.5H2O hemi-pentahydrate OR CdCl2 Anhydrous.
Molecular Weight: 228.35 hemi-pentahydrate OR 183.32 Anhydrous.

Section 10. Stability and Reactivity

Chemical Stability: Stable under normal temperatures and pressures.
Incompatibility (Materials to Avoid):
Oxidizing agents.
Conditions to Avoid: Incompatible materials, exposure to moist air or water, excessive heat.
Hazardous Decomposition Products: Cadmium oxides, chlorine or hydrochloric acid may evolve.
Hazardous Polymerization:
Will not occur.

Section 11. Toxicological Information

Toxicity to Animals: LD50 Oral - Rat - 88 mg/kg for anhydrous material.
Carcinogenicity: IARC: 1 - Group 1: Carcinogenic to humans. NTP: Known to be human carcinogen.
Specific target organ toxicity: May cause damage to organs through prolonged or repeated exposure. Overexposure may cause reproductive disorder(s) based on tests with laboratory animals. May cause congenital malformation in the fetus. Presumed human reproductive toxicant.

Section 12. Ecological Information

Ecotoxicity: Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.
Toxicity to fish: LC50 - Oncorhynchus mykiss (rainbow trout) - 0.003 mg/l - 96.0 h
Toxicity to daphnia and other aquatic invertebrates: Immobilization EC50 - Daphnia magna (Water flea) - 0.016 mg/l - 48 h
Persistence and Degradability: This product is not readily biodegradable.
Environmental Precautions: DO NOT DISCHARGE into drains and rivers.

Section 13. Disposal Suggestions

Dispose of in accordance with all applicable local, state, and federal regulations at an approved waste disposal facility.

Section 14. Transport and Label Information

DOT USA & ADR/RID Europe:
UN-No UN 2570
Proper Shipping Name Cadmium compounds (Cadmium chloride)
Hazard Class 6.1, Packing Group III
IMDG/IMO
UN-No UN 2570
Proper Shipping Name Cadmium compounds (Cadmium chloride)
Hazard Class 6.1, Packing Group III
IATA:
UN-No UN 2570
Proper Shipping Name Cadmium compounds (Cadmium chloride)
Hazard Class 6.1, Packing Group III

Section 15. Regulatory Information

USA:
OSHA Hazards
: Carcinogen, Target Organ Effect, Highly toxic by inhalation, Toxic by ingestion, Teratogen, Mutagen.
SARA 302: No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SARA 313 Components: The following components are subject to reporting levels established by SARA Title III, Section 313: Cadmium chloride.
SARA 311/312: Hazardous Categorization: Acute Health Hazard; Chronic Health Hazard.
California Prop.65: WARNING! This product contains a chemical known to the State of California to cause birth defects or other reproductive harm. Cadmium chloride.

Section 16. Other Information

European Labeling in Accordance with EC Directives:
H301 Toxic if swallowed.
H330 Fatal if inhaled.
H340 May cause genetic defects.
H350 May cause cancer.
H360 May damage fertility or the unborn child.
H372 Cause damage to organs through prolonged or repeated exposure.
H410 Very toxic to aquatic life with long lasting effects.

Classification according to EU Directives 67/548/EEC or 1999/45/EC:
Hazard Symbol:
T Toxic
Xn Harmful
N Dangerous for the environment.
Risk Phrase:
R25 Toxic if swallowed.
R26 Very toxic by inhalation.
R33 Danger of cumulative effects.
R45 May cause cancer.
R46 May cause inheritable genetic damage.
R61 May cause harm to the unborn child.
R48 Danger of serious damage to health by prolonged exposure.
R50 Very toxic to aquatic organisms.
R53 May cause long-term adverse effects in the aquatic environment.

Disclaimer:
**************************
Our company provides this MSDS sheet in good faith but makes no representation as to its comprehensiveness or accuracy. This SDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. The above information has been compiled from various sources and has the possibility of discrepancy and being out-dated information. Individuals receiving the information must exercise their independent judgment and do further search in determining its appropriateness for a particular purpose. In no case shall our company be liable to loss or damages by the product user.
**************************