Medium-chain Triglycerides MCT BP Ph Eur USP NF Oil Caprylic Capric Triglyceride CCTG Glyceryl Tricaprylate Caprate GTCC Fractionated Coconut Oil Manufacturers, with SDS
Supplier, Manufacturer, Exporter of Medium-chain Triglycerides, Muby Chemicals of Mubychem Group, established in 1976, is the original manufacturers of Specialty Chemicals, Pharmaceutical Excipient, Fragrance Food & Flavor chemicals, Reagent Grade Chemicals, Shale Gas Fracturing Chemicals in India. Mubychem Group has several manufacturing facilities spread across Western India and world wide contacts and toll manufacturers. We are exporting globally to countries like USA, Canada, Europe, UAE, South Africa, Tanzania, Kenya, Egypt, Nigeria, Cameroon, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Dubai, Korea, Vietnam, Thailand, Malaysia, Indonesia, Australia, China, Germany, France, Italy, Portugal, Bangladesh, etc.
The products are offered as per required specifications and in correct shape and size in mm or meshs or microns as specified by the buyer.
The participating units have one or more accreditations like FDA - cGMP and GLP approval, ISO-9001 Certified, "REACH" Registered, ISO-14001, ISO/IEC 17025, ISO-22000, FSSC 22000, ISO 45001, Kosher Certified, Halal Certified, HACCP, FSSAI. We offer Commercial Pure & IP BP EP Ph Eur USP NF JP FCC Food Grade Analytical Reagent Grades of Chemicals
Bookmark this Web Site -- or -- Email This Page Info to a Colleague or Yourself Search our website here:
Medium-chain Triglycerides MCT Oil Caprylic Capric Triglyceride CCTG Glyceryl Tricaprylate Caprate GTCC Fractionated Coconut Oil: CAS Number: 73398-61-5, EINECS EC Number: 277-452-2, Molecular Formula: yy, Molecular Weight: yy, HS Code ---**
How big is your requirement or how small
We serve it all.Specifications, Safety Data Sheet, Manufacturing process details, Wholesale retail buy sell prices, Uses etc available on line in these pages for Medium-chain Triglycerides BP Ph Eur Grade USP NF Medium Chain Triglyceride MCT Oil Caprylic Capric Triglyceride CCTG Glyceryl Tricaprylate Caprate GTCC Fractionated Coconut Oil.
For SDS MSDS Sheet Click
SDS MSDS Sheet of Medium-chain Triglycerides BP Ph Eur Grade USP NF Medium Chain Triglyceride MCT Oil Caprylic Capric Triglyceride CCTG Glyceryl Tricaprylate Caprate GTCC Fractionated Coconut Oil ManufacturersMedium-chain Triglycerides
BP Ph Eur Grade USP NF MCT Oil Caprylic Capric Triglyceride CCTG Glyceryl Tricaprylate Caprate GTCC Fractionated Coconut Oil Pure Suppliers
Medium-chain Triglycerides BP Ph Eur Grade Specifications:
Medium Chain Triglyceride (MCT Oil)
Caprylic Capric Triglyceride (CCTG)
Glyceryl Tricaprylate/Caprate (GTCC)
Fractionated Coconut OilWhen Medium-chain Triglycerides are prepared from the endosperm of Cocos nucifera L the title fractionated coconut oil may be used.
Action and use: Excipient.DEFINITION
Mixture of triglycerides of saturated fatty acids, mainly of caprylic (octanoic) acid and of capric (decanoic) acid. The fatty acids are obtained from the oil extracted from the hard, dried fraction of the endosperm of Cocos nucifera L. or from the dried endosperm of Elaeis guineensis Jacq.
Content: Minimum 95.0 per cent of saturated fatty acids with 8 and 10 carbon atoms.CHARACTERS
Appearance: Colourless or slightly yellowish, oily liquid.
Solubility: Practically insoluble in water, miscible with ethanol (96 per cent), with methylene chloride, with light petroleum and with fatty oils.
Relative density: About 0.95.
Refractive index: About 1.446.IDENTIFICATION
First identification: C, D
Second identification: A, B, D
A. Iodine value: maximum 1.0.
B. Saponification value: 310 to 360.
C. Composition of fatty acids (see Tests).
D. Viscosity (see Tests).TESTS
Appearance: The substance to be examined is clear and not more intensely coloured than reference solution.
Alkaline impurities: Dissolve 2.00 g in a mixture of 1.5 mL of ethanol (96 per cent) and 3.0 mL of ether. Add 0.05 mL of bromophenol blue solution. Not more than 0.15 mL of 0.01 M hydrochloric acid is required to change the colour of the indicator to yellow.
Viscosity: 25 mPa⋅s to 33 mPa⋅s.
Acid value: Maximum 0.2.
Hydroxyl value: Maximum 10.
Peroxide value: Maximum 1.0.
Composition of fatty acids: To pass the test.
Composition of the fatty-acid fraction of the substance:
- caproic acid: maximum 2.0 per cent;
- caprylic acid: 50.0 per cent to 80.0 per cent;
- capric acid: 20.0 per cent to 50.0 per cent;
- lauric acid: maximum 3.0 per cent;
- myristic acid: maximum 1.0 per cent;
- fatty acids of chain length greater than or equal to C16: maximum 1.0 per cent.
Atomic absorption spectrometry: To pass the test.
Chromium: Maximum 0.05 ppm, if intended for use in parenteral nutrition.
Copper: Maximum 0.1 ppm, if intended for use in parenteral nutrition.
Lead: Maximum 0.1 ppm, if intended for use in parenteral nutrition.
Nickel: Maximum 0.2 ppm, if intended for use in parenteral nutrition.
Tin: Maximum 0.1 ppm, if intended for use in parenteral nutrition.
Water: Maximum 0.2 per cent, determined on 1.00 g.
Sulfated ash: Maximum 0.1 per cent, determined on 2.0 g.Medium-Chain Triglycerides USP NF Grade Specifications:
Glycerides, mixed decanoyl and octanoyl.
Caprylic and capric triglycerides.Medium-Chain Triglycerides consist of a mixture of triglycerides of saturated fatty acids, mainly of caprylic acid (C8H16O2) and capric acid (C10H20O2). The fatty acids are derived from the oil extracted from the hard, dried fraction of the endosperm of Cocos nucifera L. or from the dried endosperm of Elaeis guineensis Jacq. They contain not less than 95 percent of saturated fatty acids with 8 and 10 carbon atoms.
Packaging and storage: Preserve in tight containers, protected from light. Store at temperatures not exceeding 25C.
Labeling: Where it is intended for use in parenteral nutrition, it is so labeled.
Appearance: The substance is clear and not more intensely colored than a solution prepared immediately before use by mixing 2.4 mL of ferric chloride and 0.6 mL of cobaltous chloride with Diluent, prepared as directed below, to make 10.0 mL, and diluting 5.0 mL of the solution so obtained with Diluent to make 10.0 mL. Make the comparison by viewing the substance and the solution downward in matched color-comparison tubes against a white surface
Diluent: Transfer 27.5 mL of hydrochloric acid to a 1000-mL volumetric flask, and dilute with water to volume.
Identification:
A: It meets the requirements of the test for Saponification value.
B: It meets the requirements of the test for Fatty acid composition.
Specific gravity: between 0.93 and 0.96, at 20 .
Acid value: not more than 0.2.
Hydroxyl value: not more than 10.
Iodine value: not more than 1.0.
Peroxide value: not more than 1.0.
Saponification value: between 310 and 360, determined on 1.0 g.
Unsaponifiable matter: not more than 0.5%, determined on 5.0 g.
Fatty acid composition: The fatty acid fraction of Medium-Chain Triglycerides exhibits the following composition, as determined in the section Fatty Acid Composition. Disregard any peak with an area less than 0.05% of the total area:
Carbon-Chain Length & Percentage:
6: 2%
8: 50-80%
10: 20-50%
12: 3%
14: 1%
Viscosity: between 25 and 33 centipoises determined at 20 ± 0.1 with a capillary viscosimeter.
Refractive index: between 1.440 and 1.452, at 20.
Alkaline impurities: Dissolve 2.0 g of Medium-Chain Triglycerides in a mixture of 1.5 mL of alcohol and 3.0 mL of ethyl ether. Add 0.05 mL of bromophenol blue, and titrate with 0.01 N hydrochloric acid to a yellow endpoint: not more than 0.15 mL of 0.01 N hydrochloric acid is required.
Water: not more than 0.2%.
Total ash: not more than 0.1%, determined on 2.0 g.
Heavy metals: [NOTE—Use this test for Medium-Chain Triglycerides intended for use other than in parenteral nutrition.]. To pass the test.
Limit of chromium: [NOTE—Use this test for Medium-Chain Triglycerides intended for use in parenteral nutrition.]. To pass the test.
Limit of copper: [NOTE—Use this test for Medium-Chain Triglycerides intended for use other than in parenteral nutrition.]. To pass the test.
Limit of lead: [NOTE—Use this test for Medium-Chain Triglycerides intended for use other than in parenteral nutrition.]. To pass the test.
Limit of nickel: [NOTE—Use this test for Medium-Chain Triglycerides intended for use other than in parenteral nutrition.]. To pass the test.
Limit of tin: [NOTE—Use this test for Medium-Chain Triglycerides intended for use other than in parenteral nutrition.]. To pass the test.For Original Monographs of IP Indian Pharmacopoeia BP British Pharmacopoeia USP US Pharmacopoeia FCC Food Grade product, please check with the respective web-pages or books.
We also manufacture and supply as under:
Medium-chain Triglycerides MCT Oil
Manufacturers:
MUBY CHEMICALS
Ambernath Mumbai, Ankleshwar Gujarat, India
TEL: (OFFICE) +912223770100, +912223726950
Current Date Time in India GMT+5:30e-mail: info@mubychem.com
USA, Canada, Mexico and other American
neighbouring buyers may
e-mail: us@mubychem.com
Call toll-free 1-877-682-9243 (1-877-MUBYCHEM)
Copyright and Usual Disclaimer is Applicable.
Last 13 June, 2024
Exporters to USA Canada UAE Europe South Africa Tanzania Kenya Uganda Egypt Nigeria Turkey Mexico Brazil Argentina Chile Dubai etc.
Global or International Suppliers, Exporters, Importers, Manufacturers
I shall pass through this world, but once. If therefore, there is any good that I can do, or if there is any favor that I can show to a fellow human being, let me do it now. Let me not defer or neglect it. For I shall not tread this way again
Medium-chain Triglycerides MCT Oil Caprylic Capric Triglyceride CCTG Glyceryl Tricaprylate Caprate GTCC
SDS, Safety Data Sheet
MSDS Sheet, Material Safety Data Sheet 22-Dec-20Section 1: Chemical Product and Company Identification
Product Name & Other Names: Medium-chain Triglycerides MCT Oil Caprylic Capric Triglyceride CCTG Glyceryl Tricaprylate Caprate GTCC.
CAS Number: 73398-61-5
EINECS EC Code: 277-452-2
Relevant uses and uses advised against (if any): Industrial Manufacturing.
Suppliers: As per letterhead.Section 2: Hazards Identification
GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Hazard Class and Category Code(s), Regulation (EC) No 1272/2008 (CLP)Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.
This substance is not classified as dangerous according to Directive 67/548/EEC.Labeling as per GHS and Regulation EC 1272/2008 (CLP) & GHS
GHS Label Elements
NONESignal Word: None
Hazards not otherwise classified (HNOC):
May causes mild skin irritation.
May causes mild eye irritation.Precautionary statements:
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P262: Do not get in eyes, on skin, or on clothing.
P281: Use personal protective equipment as required.
P302+P352: IF ON SKIN: Wash with plenty of soap and water.
P304+P340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337+313: If eye irritation persists get medical advice/attention.Section 3: Composition and Information on Ingredients
Product Name & Other Names: Medium-chain Triglycerides MCT Oil Caprylic Capric Triglyceride CCTG Glyceryl Tricaprylate Caprate GTCC.
CAS Number: 73398-61-5
EINECS EC Code: 277-452-2Section 4: First Aid Measures
Always seek medical advice after the first aid treatment.
Skin: Rinse with water. Soap may be used. Seek Medical Aid.
Eyes: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally. Seek Medical Aid.
Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Ingestion: If swallowed, induce vomiting immediately after giving two glasses of water. Never give anything by mouth to an unconscious person.Section 5: Fire and Explosion Data
Flammability of the Product: Non-flammable.
Products of Combustion: Oxides of Carbon.
Fire Fighting Media and Instructions: Use water spray, alcohol-resistant foam, dry chemical, or carbon dioxide. Wear self-contained breathing apparatus for firefighting if necessary.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures under fire conditions, it may produce toxic or irritating fumes. Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method according to the surrounding situation is used. Uninvolved persons should evacuate to a safe place.Section 6: Accidental Release Measures
Personal precautions, protective equipment, and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment Cleanup procedures and Storage:
Small Spill: Use appropriate tools to put the spilled solid in a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and dispose of according to legal requirements.
Large Spill: Contain spilled material. Do not let the product enter drains. Use a shovel to put the material into a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and allow evacuating as per law.Section 7: Handling and Storage
Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid contact with skin and eyes. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like strong oxidizing agents.Section 8: Exposure Controls/Personal Protection
Engineering Controls: Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. If user operations generate dust, fume, or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice. Wash hands after handling.Section 9: Physical and Chemical Properties
Physical state and appearance: Clear colorless, transparent, viscous liquid.
Odor: Mild, characteristic.
Odor threshold: Not available.
pH: Not available.
Relative density: around 0.93 – 0.96 literature.
Melting point: About 66C
Initial boiling point and boiling range: around 220C-230C literature.
Flash point: >230C.
Auto-ignition temperature: Not available.
Decomposition temperature: >300C literature.
Upper/lower flammability or explosive limits: Not available.
Vapor pressure: Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility: Practically insoluble in water.
Viscosity: Not available.Section 10: Stability and Reactivity Data
Stability: It is stable in room temperature in closed containers under normal storage & handling.
Conditions of instability: Incompatible materials, Moisture
Incompatibility with various substances: Avoid high temperatures, sparks, open flames, and moisture. Avoid contact with strong oxidizing agents.
Polymerization: Will not occur.Section 11: Toxicological Information
LD50 Oral, Rat: > 5000 mg/kg.
LD50 Dermal, Rat: > 2000 mg/kg.
Carcinogenicity: No component of this product present at levels greater than or equal to 0.1% is identified as possible or confirmed human carcinogen by IARC, ACGIH, OSHA and NTP.
Teratogenic Effects: Not available.
Mutagenic Effects: Not available.
Developmental Toxicity: Not available.
Reproductive Effects: No information available.Section 12: Ecological Information
Toxicity: EC50 > 100 mg/l (daphnia).
Persistence and Degradability: No information available.
Mobility: No information available.
Bioaccumulation/ Accumulation: Readily biodegradable. Expected to be unlikely to bioaccumulate.
Results of PBT and vPvB assessment: No data available for assessment.
The product is not classified as environmentally hazardous. However, this does not exclude the possibility that large or frequent spills can have a harmful or damaging effect on the environment.Section 13: Disposal Considerations
Waste Disposal: Waste must be disposed of in accordance with federal, state, and local environmental control regulations.
Section 14: Transport Information
DOT USA, TDG Canada & ADR/RID Europe: Not dangerous goods
IMDG/IMO: Not dangerous goods
IATA: Not dangerous goods.Section 15: Other Regulatory Information
USA Regulations:
Section 16 - Additional Information
OSHA: None of the chemicals in this product are considered highly hazardous by OSHA.
California Prop 65: California No Significant Risk Level: None of the chemicals in this product are listed.Disclaimer:
**************************
Our company provides this MSDS sheet in good faith but makes no representation as to its comprehensiveness or accuracy. This SDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. The above information has been compiled from various sources and has the possibility of discrepancy and being out-dated information. Individuals receiving the information must exercise their independent judgment and do further search in determining its appropriateness for a particular purpose. In no case shall our company be liable to loss or damages by the product user.
**************************