Phenyl chloroformate or Phenyl chlorocarbonate or Phenyl carbonochloridate Manufacturers, with SDS GHS MSDS Sheet
Supplier, Manufacturer, Exporter of Phenyl chloroformate or Phenyl Carbonochloridate, Muby Chemicals of Mubychem Group, established in 1976, is the original manufacturers of Specialty Chemicals, Pharmaceutical Excipient, Fragrance Food & Flavor chemicals, Reagent Grade Chemicals, Shale Gas Fracturing Chemicals in India. Mubychem Group has several manufacturing facilities spread across Western India and world wide contacts and toll manufacturers. We are exporting globally to countries like USA, Canada, Europe, UAE, South Africa, Tanzania, Kenya, Egypt, Nigeria, Cameroon, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Dubai, Korea, Vietnam, Thailand, Malaysia, Indonesia, Australia, China, Germany, France, Italy, Portugal, Bangladesh, etc.
The products are offered as per required specifications and in correct shape and size in mm or meshs or microns as specified by the buyer.
The participating units have one or more accreditations like FDA - cGMP and GLP approval, ISO-9001 Certified, "REACH" Registered, ISO-14001, ISO/IEC 17025, ISO-22000, FSSC 22000, ISO 45001, Kosher Certified, Halal Certified, HACCP, FSSAI. We offer Commercial Pure & IP BP EP Ph Eur USP NF JP FCC Food Grade Analytical Reagent Grades of Chemicals
Bookmark this Web Site -- or -- Email This Page Info to a Colleague or Yourself Search our website here:
Phenyl Chloroformate or Phenyl chlorocarbonate or Phenyl carbonochloridate: CAS Number: 1885-14-9, EINECS EC Number: 217-547-8, Molecular Formula: C7H5ClO2 or ClCOOC6H5, Molecular Weight: 156.57, HS Code 2915 90 70
How big is your requirement or how small
We serve it all.Specifications, Safety Data Sheet, Manufacturing process details, Wholesale retail buy sell prices, Uses etc available on line in these pages for Phenyl Chloroformate or Phenyl chlorocarbonate or Phenyl carbonochloridate.
For SDS MSDS Sheet Click
SDS MSDS Sheet of Phenyl Chloroformate or Phenyl chlorocarbonate or Phenyl carbonochloridate ManufacturersPhenyl Chloroformate
Phenyl chlorocarbonate or Phenyl carbonochloridate Pure Suppliers
Phenyl chloroformate or Phenyl chlorocarbonate or Phenyl carbonochloridate is used in manufacturing of paint, pharmaceutical, plastic and in chemical industry.
General Properties and Specifications of Phenyl Chloroformate or Phenyl chlorocarbonate or Phenyl carbonochloridate:
CAS Number: 1885-14-9
Appearance: Clear colorless to light yellow liquid.
Odor: Pungent.
Color: 50 Apha maximum.
Assay: 99% minimum.
Acidity (as HCl): 0.2% maximum.
Phenol: 0.2% maximum.
Carbonate: 0.5% maximum.
Phosgene: 0.1% maximum.
Iron: 50 ppm maximum.
Relative density: around 1.25
Melting point: -28C.
Boiling point: 188C to 189C.
Autoignition Temperature: 540C
Flash point: 69C.
Solubility: Reacts with water.
Storage: Store at 15C to 25C.We manufacture and supply as under:
Manufacturers:
MUBY CHEMICALS
Ambernath Mumbai, Ankleshwar Gujarat, India
TEL: (OFFICE) +912223770100, +912223726950
Current Date Time in India GMT+5:30e-mail: info@mubychem.com
USA, Canada, Mexico and other American
neighbouring buyers may
e-mail: us@mubychem.com
Call toll-free 1-877-682-9243 (1-877-MUBYCHEM)
Copyright and Usual Disclaimer is Applicable.
Last 5 October, 2024
Exporters to USA Canada UAE Europe South Africa Tanzania Kenya Uganda Egypt Nigeria Turkey Mexico Brazil Argentina Chile Dubai etc.
Global or International Suppliers, Exporters, Importers, Manufacturers
I shall pass through this world, but once. If therefore, there is any good that I can do, or if there is any favor that I can show to a fellow human being, let me do it now. Let me not defer or neglect it. For I shall not tread this way again
Phenyl Chloroformate or Phenyl chlorocarbonate or Phenyl carbonochloridate SDS Safety Data Sheet
MSDS Sheet, Material Safety Data Sheet 12-Nov-20Section 1. Product Information
Product Name & Other Names: Phenyl Chloroformate or Phenyl chlorocarbonate or Phenyl carbonochloridate.
CAS No.: 1885-14-9
EINECS EC Number: 217-547-8
Chemical Formula: C7H5ClO2 or ClCOOC6H5
Molecular Weight: 156.57
Relevant uses and uses advised against (if any): Industrial Manufacturing.
Suppliers: As per letterhead.Section 2: Hazards Identification
GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008Acute toxicity, oral Category 4, H302
Skin irritation Category 2, H315
Skin sensitization, Category 1, H317
Serious eye damage Category 1, H318
Acute toxicity, inhalation Category 2, H330
Specific target organ toxicity - single exposure Category 3, Respiratory system, H335Labeling according GHS & Regulation (EC) No 1272/2008
GHS Label Elements
CorrosiveGHS Label Elements
ToxicSignal Words: Danger
Hazard statements:
H302 Harmful if swallowed.
H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H318 Causes serious eye damage.
H330 Fatal if inhaled.
H335 May cause respiratory irritation.Precautionary statements:
P202: Do not handle until all safety precautions have been read and understood.
P260: Do not breathe dust/fume/gas/mist/vapors/spray.
P264: Wash … thoroughly after handling.
P270: Do not eat, drink or smoke when using this product.
P271: Use only outdoors or in a well-ventilated area.
P273: Avoid release to the environment.
P280: Wear protective gloves/protective clothing/eye protection/face protection.
P284: Wear respiratory protection.
P301+310: IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician.
P304+340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P308+313: IF exposed or concerned: Get medical advice/attention.
P391: Collect spillage.
P405: Store locked up.
P403+233: Store in a well-ventilated place. Keep container tightly closed.
P501: Dispose of contents/container in accordance with local/regional/national/international regulation.Classification according to EU Directives 67/548/EEC or 1999/45/EC:
Hazard Symbols:
T+ Very Toxic
Xn Harmful
Xi Irritant.
Risk Phrases:
R22 Harmful if swallowed.
R26 Very toxic by inhalation.
R37/38 Irritating to respiratory system and skin.
R41 Risk of serious damage to eyes.
R43 May cause sensitization by skin contact.Section 3: Composition and Information on Ingredients
Product Name & Other Names: Phenyl Chloroformate or Phenyl chlorocarbonate or Phenyl carbonochloridate.
CAS No.: 1885-14-9
EINECS EC Number: 217-547-8Section 4. First Aid & Procedure
Always get medical attention after the first aid is over.
Ingestion: Never give anything by mouth to an unconscious person. Get medical attention.
Skin: Immediately flush skin with plenty of water for at least 15 minutes. Remove and wash contaminated clothing and shoes before reuse. Get medical attention if irritation develops.
Eyes: Immediately flush eyes with plenty of water for 15 minutes, occasionally lifting upper and lower eyelids. Hold eyelids apart during irrigation. Get medical attention.
Inhalation: Remove person to fresh air. If breathing is difficult, give oxygen. If not breathing administer artificial respiration. Get medical attention.Section 5. Fire Fighting Measures
Flash Point: 69C.
Fire/Explosion: Not considered to be a fire and explosion hazard. However, it is combustible at higher temperature. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air at elevated temperatures.
Caution! in contact with water product releases: Hydrogen chloride gas.
Extinguishing Medium: Dry chemical or carbon dioxide.
Unsuitable extinguishing media: Water, Foam.
Special hazards arising from the substance or mixture: Fumes may evolve along with carbon oxides and hydrogen chloride.
Fire Fighting Instructions: Use suitable protective equipment for surrounding fire. Suppress (knock down) gases/vapors/mists with a water spray jet.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures under fire conditions, it may produce toxic or irritating fumes. Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method according to the surrounding situation is used. Uninvolved persons should evacuate to a safe place.Section 6. Spills and Disposals
Personal precautions, protective equipment and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Ensure adequate ventilation. Don't touch or walk through this product. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material.
Environmental precautions: Do not let the product enter drains, soil or water sources.
Methods and materials used for containment Cleanup procedures and Storage: Contain spilled material. Cover with an inert, non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite). Vacuum or sweep-up and remove to an approved disposal container.Section 7. Handling and Storage
Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. Wash thoroughly after handling. Do not drink, eat or smoke while handling. Avoid contact with skin, eyes and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid prolonged or repeated exposure. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Do not leave the material container open. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid contact with skin and eyes. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like oxidizing agents, water, alcohols, amines, bases, strong oxidizing agents, metals, bases, iron. Take care to eliminate static discharge. Store at 15C to 25C.Section 8. Exposure Controls & Personal Protection
Exposure Limits: This product does not contain any hazardous materials with occupational exposure limits established by the region specific regulatory bodies..
Engineering Controls: Use adequate exhaust ventilation to keep airborne concentrations below the allowable exposure limit.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice. Wash hands after handling.Section 9. Physical & Chemical Data
Appearance: Clear colorless to light yellow liquid.
Odor: Pungent.
Odor threshold: Not available.
pH: Not available.
Relative density: around 1.25
Melting Point: -28C.
Initial boiling point and boiling range: 188C to 189C.
Flash point: 69C.
Auto-ignition temperature: 540C.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor pressure: Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility(ies): Reacts with water.
Viscosity: Not available.
Chemical Formula: C7H5ClO2 or ClCOOC6H5
Molecular Weight: 156.57Section 10. Stability and Reactivity
Chemical Stability: Stable under normal temperatures and pressures.
Incompatibility (Materials to Avoid): Oxidizing agents, water, alcohols, amines, bases, strong oxidizing agents, metals, bases, iron.
Conditions to Avoid: Incompatible materials, excessive heat.
Hazardous Decomposition Products: Fumes may evolve along with carbon oxides and hydrogen chloride.
Hazardous Polymerization: Will not occur.Section 11. Toxicological Information
Toxicity to Animals:
LC50 Inhalation - Rat: 0.18 mg/L/4h.
LD50 Oral - Rat - 1410 microL/kg.
LD50 Inhalation - Rabbit 3970 microL/kg.
Carcinogenicity: No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC, NTP ACGIH or OSHA.
Mutagenic Effects: No information found.
Reproductive Effects: No information found.
Developmental Toxicity: No information found.Section 12. Ecological Information
Toxicity to fish: LC50 Leuciscus idus (Golden orfe): 10 - 22 mg/l; 96 h.
Persistence and Degradability: No information available. However unlikely to persist due to water solubility.
Mobility: No information available. However likely to be mobile due to water solubility.
Bioaccumulation/ Accumulation: No information available.
Results of PBT and vPvB assessment: No data available for assessment.Section 13. Disposal Suggestions
Dispose of in accordance with all applicable local, state and federal regulations at an approved waste disposal facility.
Section 14. Transport and Label Information
DOT USA, TDG Canada & ADR/RID Europe:
UN-No UN 2746
Proper Shipping Name: PHENYL CHLOROFORMATE
Hazard Class 6.1 (8), Packing Group II
IMDG/IMO
UN-No UN 2746
Proper Shipping Name: PHENYL CHLOROFORMATE
Hazard Class 6.1 (8), Packing Group II
IATA:
UN-No UN 2746
Proper Shipping Name: PHENYL CHLOROFORMATE
Hazard Class 6.1 (8), Packing Group IISection 15. Regulatory Information
USA:
SARA 302: Not subject to the reporting requirements of SARA Title III, Section 302.
SARA 311/312: Acute Health Hazard; Chronic Health Hazard, as per section 2.
California Prop.65: This product contains no chemical known to the State of California to cause birth defects or other reproductive harm.Section 16. Other Information
European Labeling in Accordance with EC Directives:
Classification according to EU Directives 67/548/EEC or 1999/45/EC:
H302 Harmful if swallowed.
H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H318 Causes serious eye damage.
H330 Fatal if inhaled.
H335 May cause respiratory irritation.
Hazard Symbols:
T+ Very Toxic
Xn Harmful
Xi Irritant.
Risk Phrases:
R22 Harmful if swallowed.
R26 Very toxic by inhalation.
R37/38 Irritating to respiratory system and skin.
R41 Risk of serious damage to eyes.
R43 May cause sensitization by skin contact.Disclaimer:
**************************
Our company provides this MSDS sheet in good faith but makes no representation as to its comprehensiveness or accuracy. This SDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. The above information has been compiled from various sources and has the possibility of discrepancy and being out-dated information. Individuals receiving the information must exercise their independent judgment and do further search in determining its appropriateness for a particular purpose. In no case shall our company be liable to loss or damages by the product user.
**************************