Ammonium Persulfate Ammonium Persulphate SDS MSDS Sheet

Muby Chemicals of Mubychem Group, established in 1976, is the original manufacturers of Specialty Chemicals, Pharmaceutical Excipient, Fragrance Food & Flavor chemicals, Reagent Grade Chemicals, Shale Gas Fracturing Chemicals in India. Mubychem Group has several manufacturing facilities spread across Western India and world wide contacts and toll manufacturers. We are exporting globally to countries like USA, Canada, Europe, UAE, South Africa, Tanzania, Kenya, Egypt, Nigeria, Cameroon, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Dubai, Korea, Vietnam, Thailand, Malaysia, Indonesia, Australia, China, Germany, France, Italy, Portugal, Bangladesh, etc.

The products are offered as per required specifications and in correct shape and size in mm or meshs or microns as specified by the buyer.

The participating units have one or more accreditations like FDA - cGMP and GLP approval, ISO-9001 Certified, "REACH" Registered, ISO-14001, ISO/IEC 17025, ISO-22000, FSSC 22000, ISO 45001, Kosher Certified, Halal Certified, HACCP, FSSAI. We offer Commercial Pure & IP BP EP Ph Eur USP NF JP FCC Food Grade Analytical Reagent Grades of Chemicals
ISO9001 ISO IEC 17025 ISO14001 ISO 45001 ISO 22000 HACCP FSSC22000 HACCP GMP Good Laboratory fssai HACCP halal jkkosher allergen free Gluten Free Reach

Bookmark this Web Site

Search our website here:

Home --------- Contact

Chemical Products

Export to USA UAE Europe Africa Tanzania Kenya Egypt Turkey Jumbo Packing; Exports to USA UAE Europe Africa Tanzania Kenya Uganda Egypt Turkey Brazil Chile Argentina Dubai etc. Packing Palletized and Shrink Wrapped; 25kg or 50kg or 55 lbs HDPE laminated bags with an extra HMHDP liner Drum Packing for better transportation Drum Packing & Palletized Liquid Chemical Export Import Air Freighting

Buy-Ammonium Persulfate; Door Delivery

Ammonium Persulfate Persulphate Manufacturers Specifications

Ammonium Persulfate SDS Safety Data Sheet
MSDS Sheet, Material Safety Data Sheet
30-Nov-20

1. Product & Company Identification

Product Name & Other Names: Ammonium Persulfate or Ammonium Peroxydisulfate or Peroxydisulfuric Acid, Diammonium Salt or Diammonium peroxydisulfate.
CAS No.: 7727-54-0
EINECS EC Number: 231-786-5
Molecular Weight: 228.20
Chemical Formula: (NH4)2S2O8
Intended uses and uses advised against (if any): Oxidizer for Oil & Gas Wells and Industrial Use.
Supplier: As per letterhead.

2. Hazards Identification

GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008

Oxidizing Solids Category 3, H272
Acute toxicity - Oral Category 4, H302
Skin corrosion/irritation Category 2, H315
Serious eye damage/eye irritation Category 2A, H319
Respiratory sensitization Category 1, H334
Skin sensitization Category 1, H317
Specific target organ toxicity (single exposure) Category 3, H335

Labeling according GHS & Regulation (EC) No 1272/2008

GHS Label Elements
Oxidizing Solid
Oxidizing Solid

GHS Label Elements
Irritant
Irritant

GHS Label Elements
Health Hazard
Health Hazard

Signal Word: Danger

Hazard Statements:
H272 - May intensify fire; oxidizer
H302 - Harmful if swallowed
H315 - Causes skin irritation
H317 - May cause an allergic skin reaction
H319 - Causes serious eye irritation
H334 - May cause allergy or asthma symptoms or breathing difficulties if inhaled
H335 - May cause respiratory irritation.

Precautionary Statements - Prevention
P210: Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
P220: Keep/Store away from clothing/combustible materials
P221: Take any precaution to avoid mixing with combustibles
P261: Avoid breathing dust.
P264: Wash face, hands and any exposed skin thoroughly after handling
P270: Do not eat, drink or smoke when using this product
P271: Use only outdoors or in a well-ventilated area
P272: Contaminated work clothing should not be allowed out of the workplace.
P280: Wear protective gloves/ protective clothing/ eye protection/ face protection
P285: In case of inadequate ventilation wear respiratory protection
Precautionary Statements - Response
P301+P312: IF SWALLOWED: Call a POISON CENTER or doctor if you feel unwell.
P302+P352: IF ON SKIN: Wash with plenty of water.
P304+P341: IF INHALED: If breathing is difficult, remove to fresh air and keep at rest in a position comfortable for breathing.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P314: Get Medical advice/attention if you feel unwell.
P330: If swallowed, rinse mouth.
P333+P313: If skin irritation or rash occurs: Get medical advice/ attention.
P337+P313: If eye irritation persists: Get medical advice/ attention
P342+P311: If experiencing respiratory symptoms: Call a POISON CENTER or doctor.
P362: Take off contaminated clothing and wash before reuse.
P370+P378: In case of fire: Use water for extinction
Precautionary Statements - Storage
P402: Store in a dry place.
P403+P233: Store in a well-ventilated place. Keep container tightly closed
P501: Dispose of contents/container in accordance with local, regional, national, international regulations.

Classification according to EU Directives 67/548/EEC or 1999/45/EC:
Hazard Symbols:
O Oxidizing
Xn Harmful
Xi Irritant
Risk Phrases:
R8 = Contact with combustible material may cause fire.
R22 = Harmful if swallowed.
R36/37/38 = Irritating to eyes, respiratory system and skin.
R42/43 May cause sensitization by inhalation and skin contact.

3. Composition/Information on Ingredients

Product Name & Other Names: Ammonium Persulfate or Ammonium Peroxydisulfate or Peroxydisulfuric Acid, Diammonium Salt or Diammonium peroxydisulfate.
CAS No.: 7727-54-0
EINECS EC Number: 231-786-5
Percent: 98 - 100%

4. First Aid Measures

Always seek medical attention after first aid measures are provided.

Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Ingestion: If swallowed, do not induce vomiting. Give large quantities of water. Never give anything by mouth to an unconscious person. Get medical attention immediately.
Skin Contact: In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Cover the irritated skin with an emollient. Cold water may be used. Wash clothing & shoes before reuse. Get medical attention.
Eye Contact: Check for and remove any contact lenses. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Cold water may be used. Get medical attention.
Advice to Physician: Treat supportively.

5. Fire Fighting Measures

Fire: Ammonium Persulfate is not combustible, but substance is a strong oxidizer and its heat of reaction with reducing agents or combustibles may cause ignition. Heating releases oxygen which may intensify combustion in an existing fire.
Explosion: An explosion hazard when mixed with finely powdered organic matter, metal powder, or reducing agents.
Fire Extinguishing Media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Use means suitable for extinguishing surrounding fire. Cool containers with flooding quantities of water until well after fire is out.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures under fire conditions, it may produce toxic or irritating fumes. Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method according to the surrounding situation is used. Uninvolved persons should evacuate to a safe place.

6. Accidental Release Measures

Personal precautions, protective equipment, and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material. Keep away from drains, surface and groundwater and soil.
Environmental precautions: Do not let the product enter drains or ponds. Avoid contaminating soil and ground water.
Methods and materials used for containment Cleanup procedures and Storage:
Small Spill: Use appropriate tools to put the spilled solid in a convenient waste disposal container.
Large Spill: It is an oxidizing material. Contain spilled material. Cover with an inert, non-combustible, inorganic absorbent material, sweep up, and remove to an approved disposal container. Stop leak if without risk. Avoid contact with a combustible material (wood, paper, oil, clothing...). Keep the substance damp using water spray. Do not touch spilled material. Prevent entry into sewers. Eliminate all ignition sources. Avoid penetration into waterways, sewers, soil, or groundwater.

7. Handling and Storage

Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices with proper ventilation. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces. Containers of this material may be hazardous when empty since they retain product residues.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Store protected from heat, sparks and ignition sources and incompatible materials. Do not store with incompatible materials like reducing agents, organic material, sodium peroxide, water, powdered metals especially aluminum, bases, halides, oxidizing agents, combustible materials. Separate from combustibles, organic or other readily oxidizable materials. Avoid storage on wood floors. Containers of this material may be hazardous when empty since they retain product residues.

8. Exposure Controls/Personal Protection

Airborne Exposure Limits: - ACGIH Threshold Limit Value (TLV): 0.1 mg/m3 (TWA) as persulfate
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator (NIOSH type N95 or better filters) may be worn. If oil particles (e.g. lubricants, cutting fluids, glycerin, etc.) are present, use a NIOSH type R or P filter. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator. WARNING: Air-purifying respirators do not protect workers in oxygen-deficient atmospheres.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice. Wash hands after handling.

9. Physical and Chemical Properties

Appearance: Ammonium Persulphate is white crystals
Odor: Odorless
Odor threshold: Not available.
pH: Not available.
Relative density: 1.98
Melting Point: 120C (248F) Decomposes
Initial boiling point and boiling range: Not available.
Flash point: Not available.
Auto-ignition temperature: Not available.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor pressure: Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility: 80 g/l00 ml water @ 25C (77F)
Viscosity: Not available.

10. Stability and Reactivity

Stability: Stable under ordinary conditions of use and storage. Stability decreases in the presence of moisture
Hazardous Decomposition Products: Decomposed by moisture to form oxygen and ozone. Burning may produce nitrogen oxides, sulfur oxides, and sulfuric acid. Oxygen is released which supports combustion.
Hazardous Polymerization: Will not occur
Incompatibilities: Reducing agents, organic material, sodium peroxide, water, and powdered metals, especially aluminum. Acids, Bases, Halides, Oxidizing agents, Strong reducing agents, Combustible materials.
Conditions to Avoid: Moisture, combustible materials, and incompatibles.

11. Toxicological Information

Oral rat LD50: 740 mg/kg
LD50 Dermal > 2000 mg/kg (rat) (Ammonium Persulfate)
LC50 Inhalation > 2.95 mg/L (rat) (4-hr) (Ammonium Persulfate)
Carcinogenicity: Not listed by ACGIH, IARC, NTP, or CA Prop 65.
Mutagenic Effects: Not available.
Reproductive Effects: No information available.

12. Ecological Information

Toxicity to fish: LC50 - Oncorhynchus mykiss (rainbow trout) - 76 mg/l - 96 h
Toxicity to daphnia and other aquatic invertebrates: EC50 - Daphnia magna (Water flea) - 120 mg/l - 48
Results of PBT and vPvB assessment: This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
Persistence and Degradability: Unlikely to persist due to water solubility.
Mobility: Likely to be mobile due to water solubility.
Bioaccumulation/ Accumulation: No information available.

13. Disposal Considerations

Whatever cannot be saved for recovery or recycling should be handled as hazardous waste and sent to a RCRA approved waste facility. Processing use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state, and local requirements.

14. Transport Information

DOT USA, TDG Canada & ADR/RID Europe:
UN/NA: UN1444
Proper Shipping Name: AMMONIUM PERSULFATE
Hazard Class: 5.1
Packing Group: III
IMDG/IMO & IATA/ICAO:
UN/NA: UN1444
Proper Shipping Name: AMMONIUM PERSULPHATE
Hazard Class: 5.1
Packing Group: III

15. Regulatory Information

USA:
SARA Section 302 Extremely Hazardous Substances
: None of the chemicals in this product have a TPQ.
SARA 311/312: Acute health hazard Yes; Chronic health hazard No; Fire hazard Yes; Sudden release of pressure hazard No; Reactive Hazard No
Section 313:No chemicals are reportable under Section 313.
California No Significant Risk Level: None of the chemicals in this product are listed.

Section 16 - Additional Information

European Labeling in Accordance with EC Directives:
H272 = May intensify fire; oxidizer
H302 = Harmful if swallowed
H315 = Causes skin irritation
H317 = May cause an allergic skin reaction
H319 = Causes serious eye irritation
H334 = May cause allergy or asthma symptoms or breathing difficulties if inhaled
H335 = May cause respiratory irritation

Classification according to EU Directives 67/548/EEC or 1999/45/EC:
Hazard Symbols:
O Oxidizing
Xn Harmful
Xi Irritant
Risk Phrases:
R 8 = Contact with combustible material may cause fire.
R22 = Harmful if swallowed.
R36/37/38 = Irritating to eyes, respiratory system and skin.
R42/43 May cause sensitization by inhalation and skin contact.

DISCLAIMER: The information and recommendations set forth herein are presented in good faith and believed correct as of the date hereof. It is compiled from various sources and it is not necessarily all inclusive nor fully adequate in every circumstance. In addition, these suggestions should not be confused with nor followed in violation of applicable laws, regulations, rules or insurance requirements applicable. This MSDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a particular purpose.

Contact

MUBY CHEMICALS
Ambernath Mumbai, Ankleshwar Gujarat, India
TEL: (OFFICE) +912223770100, +912223726950
Current Date Time in India GMT+5:30

e-mail: info@mubychem.com

USA, Canada, Mexico and other American
neighbouring buyers may
e-mail: us@mubychem.com
Call toll-free 1-877-682-9243 (1-877-MUBYCHEM)

Manufacturers india
Copyright and Usual Disclaimer is Applicable.
Last 25 May, 2024

Exporter & Importer By Air Exports Exporters & Improters Ammonium Persulfate Persulphate Manufacturers

Exporters to USA Canada UAE Europe South Africa Tanzania Kenya Uganda Egypt Nigeria Turkey Mexico Brazil Argentina Chile Dubai etc.

I shall pass through this world, but once. If therefore, there is any good that I can do, or if there is any favor that I can show to a fellow human being, let me do it now. Let me not defer or neglect it. For I shall not tread this way again